Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 5 KOM
  • EATON

Technical specifications

Height38mm
Width45mm
Suitable for safety functionsNo
Depth72mm
Input current at signal 13mA
Number of digital outputs1
Number of digital inputs2
Number of HW-interfaces USB0
Supporting protocol for LONNo
Number of HW-interfaces parallel0
Number of HW-interfaces RS-2320
Supporting protocol for TCP/IPNo
Voltage type of supply voltageDC
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Supporting protocol for CANNo
Time delay at signal exchange10 - 84ms
Number of HW-interfaces RS-4220
Number of HW-interfaces other1
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for KNXNo
Type of voltage (input voltage)DC
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
With optical interfaceNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Short-circuit protection, outputs availableNo
Type of digital outputNone
Supporting protocol for other bus systemsYes
Output current0.5A
Explosion safety category for gasNone
Explosion safety category for dustNone
Appendant operation agent (Ex ia)No
Front built-in possibleNo
Wall mounting/direct mountingNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
IO link masterNo
Rail mounting possibleNo
System accessoryYes
Degree of protection (IP)IP20
Type of electric connectionSpring clamp connection
Radio standard BluetoothNo
Rack-assembly possibleNo
Number of interfaces PROFINET0
Radio standard Wi-Fi 802.11No
Number of HW-interfaces Wireless0
Fieldbus connection over separate bus coupler possibleYes
Appendant operation agent (Ex ib)No
Supporting protocol for AS-Interface Safety at WorkNo
Performance level according to EN ISO 13849-1None
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Digital inputs configurableNo
Type of output voltageDC
Supporting protocol for PROFIsafeNo
Radio standard UMTSNo
Digital outputs configurableNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET CBANo
Radio standard GPRSNo
Supply voltage DC15 - 15V
Supporting protocol for SafetyBUS pNo
Permitted voltage at output20.4 - 28.8V
Certified for UL hazardous location class IINo
Permitted voltage at input15 - 15V
Supply voltage AC 50 Hz0 - 0V
Certified for UL hazardous location class INo
Supporting protocol for PROFINET IONo
Supply voltage AC 60 Hz0 - 0V
Supporting protocol for EtherCATNo
Radio standard GSMNo
SIL according to IEC 61508None
Certified for UL hazardous location division 2No
Certified for UL hazardous location division 1No
Certified for UL hazardous location class IIINo
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group C (ethylene)No

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DIL-SWD-32-002

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 5 KOM
  • EATON

Technical specifications

Height

38mm

Width

45mm

Suitable for safety functions

Depth

72mm

Input current at signal 1

3mA

Number of digital outputs

1

Number of digital inputs

2

Number of HW-interfaces USB

0

Supporting protocol for LON

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

0

Supporting protocol for TCP/IP

Voltage type of supply voltage

DC

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces serial TTY

0

Supporting protocol for CAN

Time delay at signal exchange

10 .. 84ms

Number of HW-interfaces RS-422

0

Number of HW-interfaces other

1

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Supporting protocol for KNX

Type of voltage (input voltage)

DC

Supporting protocol for Modbus

Supporting protocol for INTERBUS

With optical interface

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Short-circuit protection, outputs available

Type of digital output

None

Supporting protocol for other bus systems

Output current

0.5A

Explosion safety category for gas

None

Explosion safety category for dust

None

Appendant operation agent (Ex ia)

Front built-in possible

Wall mounting/direct mounting

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

IO link master

Rail mounting possible

System accessory

Degree of protection (IP)

IP20

Type of electric connection

Spring clamp connection

Radio standard Bluetooth

Rack-assembly possible

Number of interfaces PROFINET

0

Radio standard Wi-Fi 802.11

Number of HW-interfaces Wireless

0

Fieldbus connection over separate bus coupler possible

Appendant operation agent (Ex ib)

Supporting protocol for AS-Interface Safety at Work

Performance level according to EN ISO 13849-1

None

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Digital inputs configurable

Type of output voltage

DC

Supporting protocol for PROFIsafe

Radio standard UMTS

Digital outputs configurable

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Radio standard GPRS

Supply voltage DC

15 .. 15V

Supporting protocol for SafetyBUS p

Permitted voltage at output

20.4 .. 28.8V

Certified for UL hazardous location class II

Permitted voltage at input

15 .. 15V

Supply voltage AC 50 Hz

0 .. 0V

Certified for UL hazardous location class I

Supporting protocol for PROFINET IO

Supply voltage AC 60 Hz

0 .. 0V

Supporting protocol for EtherCAT

Radio standard GSM

SIL according to IEC 61508

None

Certified for UL hazardous location division 2

Certified for UL hazardous location division 1

Certified for UL hazardous location class III

Certified for UL hazardous location group D (propane)

Certified for UL hazardous location group B (hydrogen)

Certified for UL hazardous location group E (metal dusts)

Certified for UL hazardous location group A (acetylene)

Certified for UL hazardous location group G (non-conductive dusts)

Certified for UL hazardous location group F (carbonaceous dusts)