Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces RS-4220
Input current at signal 14mA
Depth102mm
Height90mm
Suitable for safety functionsNo
Supporting protocol for LONNo
Number of HW-interfaces serial TTY0
Width35mm
Number of HW-interfaces USB0
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-2320
Number of HW-interfaces parallel0
Number of digital outputs4
Time delay at signal exchange0 - 0ms
Voltage type of supply voltageDC
Number of digital inputs4
Number of HW-interfaces other0
Number of HW-interfaces RS-4850
With optical interfaceNo
Type of voltage (input voltage)DC
Supporting protocol for ASINo
Supporting protocol for CANNo
Explosion safety category for dustNone
Type of digital outputOther
Supporting protocol for PROFIBUSNo
Supporting protocol for DeviceNetNo
Rail mounting possibleYes
Supporting protocol for TCP/IPNo
Explosion safety category for gasNone
Fieldbus connection over separate bus coupler possibleYes
System accessoryYes
Supporting protocol for other bus systemsYes
Supporting protocol for Data-HighwayNo
Short-circuit protection, outputs availableNo
Type of electric connectionFlat plug-in connection
Output current0.5A
Appendant operation agent (Ex ib)No
Supporting protocol for SUCONETNo
Appendant operation agent (Ex ia)No
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Degree of protection (IP)IP20
Supporting protocol for ModbusNo
Supporting protocol for SERCOSNo
Supporting protocol for SafetyBUS pNo
Radio standard BluetoothNo
Wall mounting/direct mountingYes
Performance level according to EN ISO 13849-1None
Rack-assembly possibleNo
Number of interfaces PROFINET0
Supporting protocol for AS-Interface Safety at WorkNo
Radio standard Wi-Fi 802.11No
Number of HW-interfaces Wireless0
Supporting protocol for PROFIsafeNo
Supply voltage AC 60 Hz0 - 0V
Supply voltage AC 50 Hz0 - 0V
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Permitted voltage at output20.4 - 28.8V
Supply voltage DC20.4 - 28.8V
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Permitted voltage at input20.4 - 28.8V
IO link masterNo
Type of output voltageDC
Supporting protocol for INTERBUS-SafetyNo
Front built-in possibleNo
Digital inputs configurableNo
SIL according to IEC 61508None
Digital outputs configurableNo
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Certified for UL hazardous location group B (hydrogen)No
Radio standard GSMNo
Certified for UL hazardous location division 1No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group C (ethylene)No
Radio standard GPRSNo
Radio standard UMTSNo
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location division 2No
Supporting protocol for EtherCATNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

EU5E-SWD-4D4D

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces RS-422

0

Input current at signal 1

4mA

Depth

102mm

Height

90mm

Suitable for safety functions

Supporting protocol for LON

Number of HW-interfaces serial TTY

0

Width

35mm

Number of HW-interfaces USB

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces parallel

0

Number of digital outputs

4

Time delay at signal exchange

0 .. 0ms

Voltage type of supply voltage

DC

Number of digital inputs

4

Number of HW-interfaces other

0

Number of HW-interfaces RS-485

0

With optical interface

Type of voltage (input voltage)

DC

Supporting protocol for ASI

Supporting protocol for CAN

Explosion safety category for dust

None

Type of digital output

Other

Supporting protocol for PROFIBUS

Supporting protocol for DeviceNet

Rail mounting possible

Supporting protocol for TCP/IP

Explosion safety category for gas

None

Fieldbus connection over separate bus coupler possible

System accessory

Supporting protocol for other bus systems

Supporting protocol for Data-Highway

Short-circuit protection, outputs available

Type of electric connection

Flat plug-in connection

Output current

0.5A

Appendant operation agent (Ex ib)

Supporting protocol for SUCONET

Appendant operation agent (Ex ia)

Supporting protocol for KNX

Supporting protocol for INTERBUS

Degree of protection (IP)

IP20

Supporting protocol for Modbus

Supporting protocol for SERCOS

Supporting protocol for SafetyBUS p

Radio standard Bluetooth

Wall mounting/direct mounting

Performance level according to EN ISO 13849-1

None

Rack-assembly possible

Number of interfaces PROFINET

0

Supporting protocol for AS-Interface Safety at Work

Radio standard Wi-Fi 802.11

Number of HW-interfaces Wireless

0

Supporting protocol for PROFIsafe

Supply voltage AC 60 Hz

0 .. 0V

Supply voltage AC 50 Hz

0 .. 0V

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Permitted voltage at output

20.4 .. 28.8V

Supply voltage DC

20.4 .. 28.8V

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Permitted voltage at input

20.4 .. 28.8V

IO link master

Type of output voltage

DC

Supporting protocol for INTERBUS-Safety

Front built-in possible

Digital inputs configurable

SIL according to IEC 61508

None

Digital outputs configurable

Certified for UL hazardous location class I

Certified for UL hazardous location class II

Certified for UL hazardous location class III

Certified for UL hazardous location group B (hydrogen)

Radio standard GSM

Certified for UL hazardous location division 1

Certified for UL hazardous location group A (acetylene)

Certified for UL hazardous location group F (carbonaceous dusts)

Certified for UL hazardous location group C (ethylene)

Radio standard GPRS

Radio standard UMTS

Certified for UL hazardous location group G (non-conductive dusts)

Certified for UL hazardous location group E (metal dusts)

Certified for UL hazardous location group D (propane)

Certified for UL hazardous location division 2

Supporting protocol for EtherCAT

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.