Technical specifications
Number of HW-interfaces RS-4220
Input current at signal 14mA
Depth102mm
Height90mm
Suitable for safety functionsNo
Supporting protocol for LONNo
Number of HW-interfaces serial TTY0
Width35mm
Number of HW-interfaces USB0
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-2320
Number of HW-interfaces parallel0
Time delay at signal exchange0 - 0ms
Number of HW-interfaces other0
Number of HW-interfaces RS-4850
With optical interfaceNo
Type of voltage (input voltage)DC
Supporting protocol for ASINo
Supporting protocol for CANNo
Explosion safety category for dustNone
Type of digital outputOther
Supporting protocol for PROFIBUSNo
Supporting protocol for DeviceNetNo
Rail mounting possibleYes
Supporting protocol for TCP/IPNo
Explosion safety category for gasNone
Fieldbus connection over separate bus coupler possibleYes
System accessoryYes
Supporting protocol for other bus systemsYes
Supporting protocol for Data-HighwayNo
Short-circuit protection, outputs availableNo
Type of electric connectionFlat plug-in connection
Output current0.5A
Appendant operation agent (Ex ib)No
Supporting protocol for SUCONETNo
Appendant operation agent (Ex ia)No
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusNo
Supporting protocol for SERCOSNo
Supporting protocol for SafetyBUS pNo
Radio standard BluetoothNo
Wall mounting/direct mountingYes
Performance level according to EN ISO 13849-1None
Rack-assembly possibleNo
Number of interfaces PROFINET0
Supporting protocol for AS-Interface Safety at WorkNo
Radio standard Wi-Fi 802.11No
Number of HW-interfaces Wireless0
Supporting protocol for PROFIsafeNo
Supply voltage AC 60 Hz0 - 0V
Supply voltage AC 50 Hz0 - 0V
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Permitted voltage at output20.4 - 28.8V
Supply voltage DC20.4 - 28.8V
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Permitted voltage at input20.4 - 28.8V
IO link masterNo
Type of output voltageDC
Supporting protocol for INTERBUS-SafetyNo
Front built-in possibleNo
Digital inputs configurableNo
SIL according to IEC 61508None
Digital outputs configurableNo
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Certified for UL hazardous location group B (hydrogen)No
Radio standard GSMNo
Certified for UL hazardous location division 1No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group C (ethylene)No
Radio standard GPRSNo
Radio standard UMTSNo
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location division 2No
Supporting protocol for EtherCATNo
Number of digital inputs4
Number of digital outputs4
Voltage type of supply voltageDC
Degree of protection (IP)IP20