Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Combined arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Voltage protection level L-N900kV
Number of poles1
Voltage protection level0.9kV
Max. continuous voltage DC200V
Nominal voltage DC-V
Max. PV-voltage-V
Construction size2 modular spacing
Degree of protection (IP)IP20
Lightning impulse current (10/350 µs)7kA
Signalling at the deviceOptic
Max. continuous voltage AC280V
Nominal voltage AC230V
Remote signallingNo
Follow current extinguishing capability-kA
Max. conductor cross section solid (solid, stranded)35mm²
Integrated backup fuseNo
Voltage protection level N-PE-kV
System configuration DCNo
System configuration TN-SYes
Voltage protection level (DC+/DC- - PE)-kV
Max. overcurrent protection device, series connection (fuse)-A
System configuration otherNo
Energy-coordinated protection effect with regard to the terminal equipmentNo
Voltage protection level (DC+ - DC-)-kV
Voltage protection level L-PE-kV
Max. overcurrent protection device, parallel connection (fuse)-A
Voltage switching spark gap technologyNo
Max. conductor cross section flexible (fine-strand)-mm²
System configuration TNYes
System configuration TN-C-SYes
System configuration TTYes
Specific energy (W/R)-kJ/Ohm
System configuration TN-CNo
System configuration ITNo
Overcurrent protected voltage tappingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

5094457 | V25-B+C 1+NPE

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Combined arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Voltage protection level L-N

900kV

Number of poles

1

Voltage protection level

0.9kV

Max. continuous voltage DC

200V

Nominal voltage DC

-V

Max. PV-voltage

-V

Construction size

2 modular spacing

Degree of protection (IP)

IP20

Lightning impulse current (10/350 µs)

7kA

Signalling at the device

Optic

Max. continuous voltage AC

280V

Nominal voltage AC

230V

Remote signalling

Follow current extinguishing capability

-kA

Max. conductor cross section solid (solid, stranded)

35mm²

Integrated backup fuse

Voltage protection level N-PE

-kV

System configuration DC

System configuration TN-S

Voltage protection level (DC+/DC- - PE)

-kV

Max. overcurrent protection device, series connection (fuse)

-A

System configuration other

Energy-coordinated protection effect with regard to the terminal equipment

Voltage protection level (DC+ - DC-)

-kV

Voltage protection level L-PE

-kV

Max. overcurrent protection device, parallel connection (fuse)

-A

Voltage switching spark gap technology

Max. conductor cross section flexible (fine-strand)

-mm²

System configuration TN

System configuration TN-C-S

System configuration TT

Specific energy (W/R)

-kJ/Ohm

System configuration TN-C

System configuration IT

Overcurrent protected voltage tapping

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.