Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Category type 2Yes
Construction size3 modular spacing
Nominal voltage DC-V
With remote signalling contactNo
Voltage protection level1.7kV
Max. continuous voltage AC385V
Mounting methodDIN rail (top hat rail) 35 mm
Nominal voltage AC350V
Nominal discharge surge current (8/20)20kA
Number of conductors (without earthing)-
Max. PV-voltage-V
Voltage protection level L-N-kV
Integrated backup fuseNo
Max. conductor cross section flexible (fine-strand)-mm²
Max. conductor cross section solid (solid, stranded)35mm²
Short-circuit breaking capacity (Isccr)-kA
System configuration DCNo
System configuration TNNo
System configuration TN-SNo
Voltage protection level N-PE-kV
Max. discharge surge current (8/20)40kA
Integrated short-circuit protection selective to fuse gG-A
System configuration TN-CNo
System configuration TTNo
Integrated short-circuit protectionNo
Signalling at the deviceOptic
System configuration TN-C-SNo
Max. overcurrent protection device, series connection (fuse)-A
System configuration otherNo
Degree of protection (IP)IP20
Max. overcurrent protection device, parallel connection (fuse)-A
Max. continuous voltage DC-V
System configuration ITNo
Leakage-current freeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

5094705 | V20-C 3-385

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Category type 2

Construction size

3 modular spacing

Nominal voltage DC

-V

With remote signalling contact

Voltage protection level

1.7kV

Max. continuous voltage AC

385V

Mounting method

DIN rail (top hat rail) 35 mm

Nominal voltage AC

350V

Nominal discharge surge current (8/20)

20kA

Number of conductors (without earthing)

-

Max. PV-voltage

-V

Voltage protection level L-N

-kV

Integrated backup fuse

Max. conductor cross section flexible (fine-strand)

-mm²

Max. conductor cross section solid (solid, stranded)

35mm²

Short-circuit breaking capacity (Isccr)

-kA

System configuration DC

System configuration TN

System configuration TN-S

Voltage protection level N-PE

-kV

Max. discharge surge current (8/20)

40kA

Integrated short-circuit protection selective to fuse gG

-A

System configuration TN-C

System configuration TT

Integrated short-circuit protection

Signalling at the device

Optic

System configuration TN-C-S

Max. overcurrent protection device, series connection (fuse)

-A

System configuration other

Degree of protection (IP)

IP20

Max. overcurrent protection device, parallel connection (fuse)

-A

Max. continuous voltage DC

-V

System configuration IT

Leakage-current free