Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Lightning current arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Nominal discharge surge current (8/20)50kA
Mounting methodDIN rail (top hat rail) 35 mm
With remote signalling contactNo
Lightning impulse current (10/350 µs)50kA
Voltage protection level1.7kV
Degree of protection (IP)IP20
Suitable for outdoor useNo
Follow current extinguishing capability0.1kA
Number of conductors (without earthing)-
Construction size8 modular spacing
Category type 1Yes
Integrated backup fuseNo
Voltage protection level N-PE-kV
Voltage protection level L-N1.7kV
Nominal voltage AC230V
Nominal voltage DC-V
Signalling at the deviceOptic
Max. continuous voltage DC-V
ExhaustingNo
Max. continuous voltage AC255V
Max. conductor cross section flexible (fine-strand)-mm²
Max. conductor cross section solid (solid, stranded)50mm²
Voltage protection level (DC+/DC- - PE)-kV
System configuration TN-SYes
System configuration TN-CNo
System configuration TTYes
System configuration otherNo
System configuration TN-C-SYes
System configuration DCNo
System configuration ITNo
Voltage protection level (DC+ - DC-)-kV
System configuration TNYes
Specific energy (W/R)-kJ/Ohm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

5096836 | MCD 50-B 3+1-OS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Lightning current arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Nominal discharge surge current (8/20)

50kA

Mounting method

DIN rail (top hat rail) 35 mm

With remote signalling contact

Lightning impulse current (10/350 µs)

50kA

Voltage protection level

1.7kV

Degree of protection (IP)

IP20

Suitable for outdoor use

Follow current extinguishing capability

0.1kA

Number of conductors (without earthing)

-

Construction size

8 modular spacing

Category type 1

Integrated backup fuse

Voltage protection level N-PE

-kV

Voltage protection level L-N

1.7kV

Nominal voltage AC

230V

Nominal voltage DC

-V

Signalling at the device

Optic

Max. continuous voltage DC

-V

Exhausting

Max. continuous voltage AC

255V

Max. conductor cross section flexible (fine-strand)

-mm²

Max. conductor cross section solid (solid, stranded)

50mm²

Voltage protection level (DC+/DC- - PE)

-kV

System configuration TN-S

System configuration TN-C

System configuration TT

System configuration other

System configuration TN-C-S

System configuration DC

System configuration IT

Voltage protection level (DC+ - DC-)

-kV

System configuration TN

Specific energy (W/R)

-kJ/Ohm

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.