Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Lightning current arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Suitable for outdoor useNo
With remote signalling contactNo
Number of conductors (without earthing)-
Specific energy (W/R)-kJ/Ohm
Max. conductor cross section flexible (fine-strand)-mm²
System configuration TN-C-SNo
Voltage protection level (DC+/DC- - PE)-kV
Nominal voltage DC-V
System configuration ITNo
Voltage protection level N-PE-kV
System configuration TN-SNo
Voltage protection level L-N-kV
Max. continuous voltage DC-V
System configuration otherNo
System configuration TNNo
Integrated backup fuseNo
System configuration DCNo
Voltage protection level (DC+ - DC-)-kV
System configuration TN-CNo
System configuration TTNo
Lightning impulse current (10/350 µs)50kA
Category type 1Yes
Signalling at the deviceNone
Max. continuous voltage AC255V
Degree of protection (IP)IP20
Nominal voltage AC230V
Voltage protection level2.0kV
Max. conductor cross section solid (solid, stranded)50mm²
ExhaustingNo
Nominal discharge surge current (8/20)50kA
Follow current extinguishing capability25kA
Mounting methodDIN rail (top hat rail) 35 mm
Construction size8 modular spacing
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

5096878 | MC 50-B 3+1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Lightning current arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Suitable for outdoor use

With remote signalling contact

Number of conductors (without earthing)

-

Specific energy (W/R)

-kJ/Ohm

Max. conductor cross section flexible (fine-strand)

-mm²

System configuration TN-C-S

Voltage protection level (DC+/DC- - PE)

-kV

Nominal voltage DC

-V

System configuration IT

Voltage protection level N-PE

-kV

System configuration TN-S

Voltage protection level L-N

-kV

Max. continuous voltage DC

-V

System configuration other

System configuration TN

Integrated backup fuse

System configuration DC

Voltage protection level (DC+ - DC-)

-kV

System configuration TN-C

System configuration TT

Lightning impulse current (10/350 µs)

50kA

Category type 1

Signalling at the device

None

Max. continuous voltage AC

255V

Degree of protection (IP)

IP20

Nominal voltage AC

230V

Voltage protection level

2.0kV

Max. conductor cross section solid (solid, stranded)

50mm²

Exhausting

Nominal discharge surge current (8/20)

50kA

Follow current extinguishing capability

25kA

Mounting method

DIN rail (top hat rail) 35 mm

Construction size

8 modular spacing