Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Frequency50 - 60Hz
Rated insulation voltage Ui440V
Release characteristicD
Pollution degree2
Rated current25A
Rated voltage400V
Over voltage category3
Voltage typeAC
Current limiting class3
Built-in depth75mm
Number of protected poles2
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core2.5 - 50mm²
Degree of protection (IP)IP20
Width in number of modular spacings3
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Number of poles (total)2
Connectable conductor cross section multi-wired2.5 - 50mm²
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

PLHT-D25/2

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Release characteristic

D

Pollution degree

2

Rated current

25A

Rated voltage

400V

Over voltage category

3

Voltage type

AC

Current limiting class

3

Built-in depth

75mm

Number of protected poles

2

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

2.5 .. 50mm²

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Number of poles (total)

2

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.