Technical specifications

Voltage typeAC
Built-in depth70mm
Rated voltage400V
Rated insulation voltage Ui500V
Release characteristicC
Degree of protection (IP)IP20
Pollution degree2
Over voltage category3
Number of protected poles4
Rated short-circuit breaking capacity according to IEC 60947-20kA
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Surge current capacity0.25kA
With interlocking deviceNo
Suitable for flush-mounted installationNo
Current limiting class3
Concurrently switching neutral conductorYes
Frequency50 Hz
Width in number of modular spacings4
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity according to EN 610096kA
Rated current16A
Rated fault current0.1A
Leakage current typeA
Number of poles (total)4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

mRB6-16/3N/C/01-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Built-in depth

70mm

Rated voltage

400V

Rated insulation voltage Ui

500V

Release characteristic

C

Degree of protection (IP)

IP20

Pollution degree

2

Over voltage category

3

Number of protected poles

4

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Surge current capacity

0.25kA

With interlocking device

Suitable for flush-mounted installation

Current limiting class

3

Concurrently switching neutral conductor

Frequency

50 Hz

Width in number of modular spacings

4

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated current

16A

Rated fault current

0.1A

Leakage current type

A

Number of poles (total)

4

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.