Technical specifications

Rated current16A
Built-in depth70mm
Rated voltage400V
Voltage typeAC
Leakage current typeA
Rated insulation voltage Ui500V
Release characteristicC
Rated fault current0.3A
Over voltage category3
Frequency50 Hz
Surge current capacity0.25kA
Pollution degree2
Width in number of modular spacings4
Current limiting class3
Degree of protection (IP)IP20
Rated short-circuit breaking capacity according to IEC 60947-20kA
Suitable for flush-mounted installationNo
Number of protected poles4
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 40°C
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610096kA
Anti-nuisance tripping versionNo
With interlocking deviceNo
Connectable conductor cross section multi-wired1 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

mRB6-16/3N/C/03-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated current

16A

Built-in depth

70mm

Rated voltage

400V

Voltage type

AC

Leakage current type

A

Rated insulation voltage Ui

500V

Release characteristic

C

Rated fault current

0.3A

Over voltage category

3

Frequency

50 Hz

Surge current capacity

0.25kA

Pollution degree

2

Width in number of modular spacings

4

Current limiting class

3

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Suitable for flush-mounted installation

Number of protected poles

4

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 40°C

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

6kA

Anti-nuisance tripping version

With interlocking device

Connectable conductor cross section multi-wired

1 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.