Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact1
Rated operation power at AC-3, 400 V5.5kW
Suitable for emergency stopNo
With transformerNo
Rated operation current Ie11.3A
Number of indicator lights0
Overload release current setting3 - 12A
Supporting protocol for LONNo
Width45mm
Height198mm
Supporting protocol for TCP/IPNo
Number of command positions0
Depth102mm
Supporting protocol for CANNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Supporting protocol for ModbusNo
Rail mounting possibleNo
External reset possibleNo
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUSNo
Release classAdjustable
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP20
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for Foundation FieldbusNo
With short-circuit releaseYes
Supporting protocol for SERCOSNo
Supporting protocol for DeviceNet SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Rated control supply voltage Us at DC24 - 24V
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for PROFINET CBANo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPNo
With fuseNo
Type of electrical connection of main circuitScrew connection
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V12A
Rated power, 460 V, 60 Hz, 3-phase0kW
Voltage type for actuatingDC
Supporting protocol for PROFINET IONo
Rated power, 575 V, 60 Hz, 3-phase0kW
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Rated operation power at AC-3, 230 V, 3-phase3kW
Coordination class according to IEC 60947-4-3Class 1
Degree of protection (NEMA)Other
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 2, 230 V0A
Rated conditional short-circuit current, type 2, 400 V100A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DE-12-M12(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

1

Rated operation power at AC-3, 400 V

5.5kW

Suitable for emergency stop

With transformer

Rated operation current Ie

11.3A

Number of indicator lights

0

Overload release current setting

3 .. 12A

Supporting protocol for LON

Width

45mm

Height

198mm

Supporting protocol for TCP/IP

Number of command positions

0

Depth

102mm

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Supporting protocol for Modbus

Rail mounting possible

External reset possible

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

Release class

Adjustable

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP20

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for Foundation Fieldbus

With short-circuit release

Supporting protocol for SERCOS

Supporting protocol for DeviceNet Safety

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rated control supply voltage Us at DC

24 .. 24V

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Supporting protocol for PROFINET CBA

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

With fuse

Type of electrical connection of main circuit

Screw connection

Type of motor starter

Direct online starter (DOL)

Rated operation current at AC-3, 400 V

12A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Voltage type for actuating

DC

Supporting protocol for PROFINET IO

Rated power, 575 V, 60 Hz, 3-phase

0kW

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Rated operation power at AC-3, 230 V, 3-phase

3kW

Coordination class according to IEC 60947-4-3

Class 1

Degree of protection (NEMA)

Other

Temperature compensated overload protection

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 2, 230 V

0A

Rated conditional short-circuit current, type 2, 400 V

100A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.