Technical specifications

Height198mm
Width45mm
Number of auxiliary contacts as normally open contact1
External reset possibleNo
Supporting protocol for TCP/IPNo
Supporting protocol for LONNo
Number of indicator lights0
Rated operation current Ie6.6A
Supporting protocol for CANNo
Number of auxiliary contacts as normally closed contact0
Rated operation power at AC-3, 400 V3kW
Number of command positions0
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUSNo
Rail mounting possibleNo
With transformerNo
Overload release current setting3 - 12A
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Supporting protocol for ModbusNo
Supporting protocol for DeviceNetNo
Supporting protocol for PROFIBUSNo
Suitable for emergency stopNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Depth102mm
Rated control supply voltage Us at AC 50HZ230 - 230V
Supporting protocol for SERCOSNo
Rated control supply voltage Us at DC0 - 0V
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation current at AC-3, 400 V7A
Voltage type for actuatingAC
Supporting protocol for DeviceNet SafetyNo
Ambient temperature, upper operating limit55°C
Degree of protection (IP)IP20
Rated power, 575 V, 60 Hz, 3-phase0kW
Type of electrical connection for auxiliary- and control current circuitScrew connection
With fuseNo
Supporting protocol for PROFINET CBANo
With short-circuit releaseYes
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET IONo
Supporting protocol for INTERBUS-SafetyNo
Type of motor starterDirect online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase1.5kW
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Release classAdjustable
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Temperature compensated overload protectionYes
Type of electrical connection of main circuitScrew connection
Rated conditional short-circuit current, type 2, 400 V100A
Rated conditional short-circuit current, type 2, 230 V0A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Coordination class according to IEC 60947-4-3Class 1
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DE-12-M7(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Height

198mm

Width

45mm

Number of auxiliary contacts as normally open contact

1

External reset possible

Supporting protocol for TCP/IP

Supporting protocol for LON

Number of indicator lights

0

Rated operation current Ie

6.6A

Supporting protocol for CAN

Number of auxiliary contacts as normally closed contact

0

Rated operation power at AC-3, 400 V

3kW

Number of command positions

0

Supporting protocol for ASI

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Rail mounting possible

With transformer

Overload release current setting

3 .. 12A

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for PROFIBUS

Suitable for emergency stop

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Depth

102mm

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Supporting protocol for SERCOS

Rated control supply voltage Us at DC

0 .. 0V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

7A

Voltage type for actuating

AC

Supporting protocol for DeviceNet Safety

Ambient temperature, upper operating limit

55°C

Degree of protection (IP)

IP20

Rated power, 575 V, 60 Hz, 3-phase

0kW

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With fuse

Supporting protocol for PROFINET CBA

With short-circuit release

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for INTERBUS-Safety

Type of motor starter

Direct online starter (DOL)

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Supporting protocol for Foundation Fieldbus

Supporting protocol for SafetyBUS p

Release class

Adjustable

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Temperature compensated overload protection

Type of electrical connection of main circuit

Screw connection

Rated conditional short-circuit current, type 2, 400 V

100A

Rated conditional short-circuit current, type 2, 230 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Coordination class according to IEC 60947-4-3

Class 1

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A