Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width45mm
Depth102mm
Height198mm
Rated operation power at AC-3, 400 V4kW
Rated operation current Ie8.5A
Supporting protocol for DeviceNetNo
Supporting protocol for ASINo
With transformerNo
Number of indicator lights0
Overload release current setting3 - 12A
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Number of auxiliary contacts as normally closed contact0
Supporting protocol for PROFIBUSNo
Suitable for emergency stopNo
Number of auxiliary contacts as normally open contact1
Supporting protocol for LONNo
Supporting protocol for CANNo
Supporting protocol for TCP/IPNo
Supporting protocol for INTERBUSNo
Number of command positions0
Supporting protocol for other bus systemsNo
Supporting protocol for SUCONETNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at DC0 - 0V
Rail mounting possibleNo
External reset possibleNo
Rated control supply voltage Us at AC 50HZ230 - 230V
Type of electrical connection of main circuitScrew connection
Supporting protocol for PROFIsafeNo
Release classAdjustable
Temperature compensated overload protectionYes
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Rated power, 575 V, 60 Hz, 3-phase0kW
With short-circuit releaseYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SafetyBUS pNo
With fuseNo
Supporting protocol for AS-Interface Safety at WorkNo
Voltage type for actuatingAC
Rated operation power at AC-3, 230 V, 3-phase2.2kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Supporting protocol for SERCOSNo
Supporting protocol for EtherNet/IPNo
Ambient temperature, upper operating limit55°C
Type of electrical connection for auxiliary- and control current circuitScrew connection
Rated operation current at AC-3, 400 V9A
Type of motor starterDirect online starter (DOL)
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Rated conditional short-circuit current, type 2, 400 V100A
Degree of protection (IP)IP20
Rated conditional short-circuit current, type 2, 230 V0A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Coordination class according to IEC 60947-4-3Class 1
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DE-12-M9(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width

45mm

Depth

102mm

Height

198mm

Rated operation power at AC-3, 400 V

4kW

Rated operation current Ie

8.5A

Supporting protocol for DeviceNet

Supporting protocol for ASI

With transformer

Number of indicator lights

0

Overload release current setting

3 .. 12A

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for PROFIBUS

Suitable for emergency stop

Number of auxiliary contacts as normally open contact

1

Supporting protocol for LON

Supporting protocol for CAN

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Number of command positions

0

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at DC

0 .. 0V

Rail mounting possible

External reset possible

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Type of electrical connection of main circuit

Screw connection

Supporting protocol for PROFIsafe

Release class

Adjustable

Temperature compensated overload protection

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Rated power, 575 V, 60 Hz, 3-phase

0kW

With short-circuit release

Supporting protocol for INTERBUS-Safety

Supporting protocol for SafetyBUS p

With fuse

Supporting protocol for AS-Interface Safety at Work

Voltage type for actuating

AC

Rated operation power at AC-3, 230 V, 3-phase

2.2kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

Ambient temperature, upper operating limit

55°C

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rated operation current at AC-3, 400 V

9A

Type of motor starter

Direct online starter (DOL)

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Rated conditional short-circuit current, type 2, 400 V

100A

Degree of protection (IP)

IP20

Rated conditional short-circuit current, type 2, 230 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Coordination class according to IEC 60947-4-3

Class 1

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.