Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width45mm
Height242mm
With transformerNo
Suitable for emergency stopNo
Number of auxiliary contacts as normally closed contact0
Depth128mm
Number of auxiliary contacts as normally open contact1
Supporting protocol for LONNo
Number of command positions0
Supporting protocol for TCP/IPNo
Number of indicator lights0
Supporting protocol for other bus systemsNo
Supporting protocol for CANNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Rated control supply voltage Us at AC 50HZ230 - 230V
External reset possibleNo
Rail mounting possibleNo
With fuseNo
Release classAdjustable
With short-circuit releaseYes
Supporting protocol for INTERBUS-SafetyNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for SERCOSNo
Supporting protocol for EtherNet/IPNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for DeviceNet SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IONo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Voltage type for actuatingAC
Rated conditional short-circuit current, type 2, 230 V100000A
Rated power, 575 V, 60 Hz, 3-phase0kW
Ambient temperature, upper operating limit55°C
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation power at AC-3, 230 V, 3-phase5.5kW
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Degree of protection (NEMA)Other
Temperature compensated overload protectionYes
Coordination class according to IEC 60947-4-3Class 2
Rated conditional short-circuit current, type 2, 400 V100000A
Rated operation power at AC-3, 400 V12.5kW
Rated operation current Ie21.7A
Overload release current setting8 - 32A
Degree of protection (IP)IP20
Rated control supply voltage Us at DC0 - 0V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V25A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user