Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width45mm
Height242mm
With transformerNo
Suitable for emergency stopNo
Number of auxiliary contacts as normally closed contact0
Depth128mm
Number of auxiliary contacts as normally open contact1
Supporting protocol for LONNo
Overload release current setting8 - 32A
Number of command positions0
Rated operation current Ie21.7A
Supporting protocol for TCP/IPNo
Rated operation power at AC-3, 400 V12.5kW
Number of indicator lights0
Supporting protocol for other bus systemsNo
Supporting protocol for CANNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Rated control supply voltage Us at AC 50HZ230 - 230V
External reset possibleNo
Rail mounting possibleNo
With fuseNo
Release classAdjustable
Rated control supply voltage Us at DC0 - 0V
With short-circuit releaseYes
Supporting protocol for INTERBUS-SafetyNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for SERCOSNo
Degree of protection (IP)IP20
Supporting protocol for EtherNet/IPNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for DeviceNet SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IONo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Voltage type for actuatingAC
Rated conditional short-circuit current, type 2, 230 V100000A
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation current at AC-3, 400 V25A
Ambient temperature, upper operating limit55°C
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation power at AC-3, 230 V, 3-phase5.5kW
Type of motor starterDirect online starter (DOL)
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Degree of protection (NEMA)Other
Temperature compensated overload protectionYes
Coordination class according to IEC 60947-4-3Class 2
Rated conditional short-circuit current, type 2, 400 V100000A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DE-32-M25(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width

45mm

Height

242mm

With transformer

Suitable for emergency stop

Number of auxiliary contacts as normally closed contact

0

Depth

128mm

Number of auxiliary contacts as normally open contact

1

Supporting protocol for LON

Overload release current setting

8 .. 32A

Number of command positions

0

Rated operation current Ie

21.7A

Supporting protocol for TCP/IP

Rated operation power at AC-3, 400 V

12.5kW

Number of indicator lights

0

Supporting protocol for other bus systems

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Rated control supply voltage Us at AC 50HZ

230 .. 230V

External reset possible

Rail mounting possible

With fuse

Release class

Adjustable

Rated control supply voltage Us at DC

0 .. 0V

With short-circuit release

Supporting protocol for INTERBUS-Safety

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for SERCOS

Degree of protection (IP)

IP20

Supporting protocol for EtherNet/IP

Type of electrical connection of main circuit

Screw connection

Supporting protocol for DeviceNet Safety

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Voltage type for actuating

AC

Rated conditional short-circuit current, type 2, 230 V

100000A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

25A

Ambient temperature, upper operating limit

55°C

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

5.5kW

Type of motor starter

Direct online starter (DOL)

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Degree of protection (NEMA)

Other

Temperature compensated overload protection

Coordination class according to IEC 60947-4-3

Class 2

Rated conditional short-circuit current, type 2, 400 V

100000A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.