Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
Supporting protocol for INTERBUSNo
Number of auxiliary contacts as normally open contact1
Depth128mm
Supporting protocol for ASINo
With transformerNo
Supporting protocol for DeviceNetNo
Width45mm
Number of indicator lights0
Height242mm
Supporting protocol for PROFIBUSNo
Suitable for emergency stopNo
Supporting protocol for ModbusNo
Number of command positions0
Supporting protocol for LONNo
Supporting protocol for TCP/IPNo
Number of auxiliary contacts as normally closed contact0
Supporting protocol for Data-HighwayNo
Supporting protocol for CANNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Supporting protocol for PROFINET CBANo
Supporting protocol for INTERBUS-SafetyNo
With short-circuit releaseYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Voltage type for actuatingDC
Supporting protocol for SERCOSNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPNo
Type of electrical connection of main circuitScrew connection
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated operation power at AC-3, 230 V, 3-phase7.5kW
Rail mounting possibleNo
Supporting protocol for PROFIsafeNo
Rated control supply voltage Us at AC 50HZ0 - 0V
External reset possibleNo
With fuseNo
Release classAdjustable
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for DeviceNet SafetyNo
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V100000A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Coordination class according to IEC 60947-4-3Class 2
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 2, 400 V100000A
Temperature compensated overload protectionYes
Rated operation power at AC-3, 400 V15kW
Rated operation current Ie29.3A
Overload release current setting8 - 32A
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 24V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V32A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user