Technical specifications

Supporting protocol for INTERBUSNo
Number of auxiliary contacts as normally open contact1
Depth128mm
Supporting protocol for ASINo
Rated operation power at AC-3, 400 V15kW
With transformerNo
Supporting protocol for DeviceNetNo
Width45mm
Number of indicator lights0
Height242mm
Supporting protocol for PROFIBUSNo
Rated operation current Ie29.3A
Suitable for emergency stopNo
Supporting protocol for ModbusNo
Overload release current setting8 - 32A
Number of command positions0
Supporting protocol for LONNo
Supporting protocol for TCP/IPNo
Number of auxiliary contacts as normally closed contact0
Supporting protocol for Data-HighwayNo
Supporting protocol for CANNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Supporting protocol for PROFINET CBANo
Supporting protocol for INTERBUS-SafetyNo
With short-circuit releaseYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Voltage type for actuatingDC
Supporting protocol for SERCOSNo
Supporting protocol for AS-Interface Safety at WorkNo
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for EtherNet/IPNo
Type of electrical connection of main circuitScrew connection
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated operation power at AC-3, 230 V, 3-phase7.5kW
Rail mounting possibleNo
Supporting protocol for PROFIsafeNo
Rated control supply voltage Us at AC 50HZ0 - 0V
External reset possibleNo
With fuseNo
Release classAdjustable
Type of motor starterDirect online starter (DOL)
Type of electrical connection for auxiliary- and control current circuitScrew connection
Degree of protection (IP)IP20
Supporting protocol for DeviceNet SafetyNo
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation current at AC-3, 400 V32A
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V100000A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Coordination class according to IEC 60947-4-3Class 2
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 2, 400 V100000A
Temperature compensated overload protectionYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DE-32-M32(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Supporting protocol for INTERBUS

Number of auxiliary contacts as normally open contact

1

Depth

128mm

Supporting protocol for ASI

Rated operation power at AC-3, 400 V

15kW

With transformer

Supporting protocol for DeviceNet

Width

45mm

Number of indicator lights

0

Height

242mm

Supporting protocol for PROFIBUS

Rated operation current Ie

29.3A

Suitable for emergency stop

Supporting protocol for Modbus

Overload release current setting

8 .. 32A

Number of command positions

0

Supporting protocol for LON

Supporting protocol for TCP/IP

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for Data-Highway

Supporting protocol for CAN

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Supporting protocol for PROFINET CBA

Supporting protocol for INTERBUS-Safety

With short-circuit release

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Voltage type for actuating

DC

Supporting protocol for SERCOS

Supporting protocol for AS-Interface Safety at Work

Rated control supply voltage Us at DC

24 .. 24V

Supporting protocol for EtherNet/IP

Type of electrical connection of main circuit

Screw connection

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated operation power at AC-3, 230 V, 3-phase

7.5kW

Rail mounting possible

Supporting protocol for PROFIsafe

Rated control supply voltage Us at AC 50HZ

0 .. 0V

External reset possible

With fuse

Release class

Adjustable

Type of motor starter

Direct online starter (DOL)

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Degree of protection (IP)

IP20

Supporting protocol for DeviceNet Safety

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

32A

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 230 V

100000A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Coordination class according to IEC 60947-4-3

Class 2

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 2, 400 V

100000A

Temperature compensated overload protection