Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth102mm
Number of command positions0
Rated operation power at AC-3, 400 V5.5kW
Number of auxiliary contacts as normally open contact0
Height198mm
Width45mm
With transformerNo
Supporting protocol for LONNo
Number of auxiliary contacts as normally closed contact1
Rated operation current Ie11.3A
Number of indicator lights0
Overload release current setting3 - 12A
Suitable for emergency stopNo
Supporting protocol for TCP/IPNo
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFIBUSNo
Rail mounting possibleNo
External reset possibleNo
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Rated control supply voltage Us at DC24 - 24V
Degree of protection (IP)IP20
Supporting protocol for SUCONETNo
Supporting protocol for ASINo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for DeviceNetNo
Supporting protocol for SERCOSNo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for other bus systemsYes
With short-circuit releaseYes
With fuseNo
Supporting protocol for DeviceNet SafetyNo
Type of electrical connection of main circuitScrew connection
Release classAdjustable
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SafetyBUS pNo
Type of motor starterDirect online starter (DOL)
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Voltage type for actuatingDC
Rated operation power at AC-3, 230 V, 3-phase3kW
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Coordination class according to IEC 60947-4-3Class 1
Ambient temperature, upper operating limit55°C
Rated operation current at AC-3, 400 V12A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 230 V0A
Rated conditional short-circuit current, type 2, 400 V100A
Degree of protection (NEMA)Other
Rated power, 575 V, 60 Hz, 3-phase0kW
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DEA-12-M12(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth

102mm

Number of command positions

0

Rated operation power at AC-3, 400 V

5.5kW

Number of auxiliary contacts as normally open contact

0

Height

198mm

Width

45mm

With transformer

Supporting protocol for LON

Number of auxiliary contacts as normally closed contact

1

Rated operation current Ie

11.3A

Number of indicator lights

0

Overload release current setting

3 .. 12A

Suitable for emergency stop

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

Supporting protocol for PROFIBUS

Rail mounting possible

External reset possible

Supporting protocol for INTERBUS

Supporting protocol for CAN

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated control supply voltage Us at DC

24 .. 24V

Degree of protection (IP)

IP20

Supporting protocol for SUCONET

Supporting protocol for ASI

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Supporting protocol for Modbus

Supporting protocol for INTERBUS-Safety

Supporting protocol for other bus systems

With short-circuit release

With fuse

Supporting protocol for DeviceNet Safety

Type of electrical connection of main circuit

Screw connection

Release class

Adjustable

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Type of motor starter

Direct online starter (DOL)

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Voltage type for actuating

DC

Rated operation power at AC-3, 230 V, 3-phase

3kW

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Coordination class according to IEC 60947-4-3

Class 1

Ambient temperature, upper operating limit

55°C

Rated operation current at AC-3, 400 V

12A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Temperature compensated overload protection

Rated conditional short-circuit current, type 2, 230 V

0A

Rated conditional short-circuit current, type 2, 400 V

100A

Degree of protection (NEMA)

Other

Rated power, 575 V, 60 Hz, 3-phase

0kW

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.