Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width45mm
Height198mm
Depth102mm
With transformerNo
Rated operation power at AC-3, 400 V4kW
Number of command positions0
Supporting protocol for CANNo
Supporting protocol for TCP/IPNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFIBUSNo
Supporting protocol for LONNo
Overload release current setting3 - 12A
Rated control supply voltage Us at AC 50HZ0 - 0V
Number of indicator lights0
Number of auxiliary contacts as normally open contact0
Supporting protocol for ModbusNo
Rated operation current Ie8.5A
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for DeviceNetNo
Supporting protocol for other bus systemsYes
Rated control supply voltage Us at DC24 - 24V
External reset possibleNo
Supporting protocol for ASINo
Rail mounting possibleNo
Supporting protocol for INTERBUSNo
Suitable for emergency stopNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SERCOSNo
Number of auxiliary contacts as normally closed contact1
Degree of protection (IP)IP20
With short-circuit releaseYes
Type of electrical connection for auxiliary- and control current circuitScrew connection
Type of electrical connection of main circuitScrew connection
Release classAdjustable
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
With fuseNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for DeviceNet SafetyNo
Type of motor starterDirect online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase2.2kW
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Voltage type for actuatingDC
Rated operation current at AC-3, 400 V9A
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 2, 400 V100A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 2, 230 V0A
Rated power, 575 V, 60 Hz, 3-phase0kW
Ambient temperature, upper operating limit55°C
Temperature compensated overload protectionYes
Coordination class according to IEC 60947-4-3Class 1
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Degree of protection (NEMA)Other
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DEA-12-M9(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width

45mm

Height

198mm

Depth

102mm

With transformer

Rated operation power at AC-3, 400 V

4kW

Number of command positions

0

Supporting protocol for CAN

Supporting protocol for TCP/IP

Supporting protocol for SUCONET

Supporting protocol for PROFIBUS

Supporting protocol for LON

Overload release current setting

3 .. 12A

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Number of indicator lights

0

Number of auxiliary contacts as normally open contact

0

Supporting protocol for Modbus

Rated operation current Ie

8.5A

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Rated control supply voltage Us at DC

24 .. 24V

External reset possible

Supporting protocol for ASI

Rail mounting possible

Supporting protocol for INTERBUS

Suitable for emergency stop

Supporting protocol for Data-Highway

Supporting protocol for SERCOS

Number of auxiliary contacts as normally closed contact

1

Degree of protection (IP)

IP20

With short-circuit release

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Type of electrical connection of main circuit

Screw connection

Release class

Adjustable

Supporting protocol for INTERBUS-Safety

Supporting protocol for AS-Interface Safety at Work

With fuse

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet Safety

Type of motor starter

Direct online starter (DOL)

Rated operation power at AC-3, 230 V, 3-phase

2.2kW

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Voltage type for actuating

DC

Rated operation current at AC-3, 400 V

9A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 2, 400 V

100A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 230 V

0A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Ambient temperature, upper operating limit

55°C

Temperature compensated overload protection

Coordination class according to IEC 60947-4-3

Class 1

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Degree of protection (NEMA)

Other

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.