Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-DEA-12-M9(24VDC)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Width
45mm
Height
198mm
Depth
102mm
With transformer
Rated operation power at AC-3, 400 V
4kW
Number of command positions
0
Supporting protocol for CAN
Supporting protocol for TCP/IP
Supporting protocol for SUCONET
Supporting protocol for PROFIBUS
Supporting protocol for LON
Overload release current setting
3 .. 12A
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Number of indicator lights
0
Number of auxiliary contacts as normally open contact
0
Supporting protocol for Modbus
Rated operation current Ie
8.5A
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Supporting protocol for DeviceNet
Supporting protocol for other bus systems
Rated control supply voltage Us at DC
24 .. 24V
External reset possible
Supporting protocol for ASI
Rail mounting possible
Supporting protocol for INTERBUS
Suitable for emergency stop
Supporting protocol for Data-Highway
Supporting protocol for SERCOS
Number of auxiliary contacts as normally closed contact
1
Degree of protection (IP)
IP20
With short-circuit release
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Type of electrical connection of main circuit
Screw connection
Release class
Adjustable
Supporting protocol for INTERBUS-Safety
Supporting protocol for AS-Interface Safety at Work
With fuse
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet Safety
Type of motor starter
Direct online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase
2.2kW
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Voltage type for actuating
DC
Rated operation current at AC-3, 400 V
9A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 400 V
100A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 2, 230 V
0A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Ambient temperature, upper operating limit
55°C
Temperature compensated overload protection
Coordination class according to IEC 60947-4-3
Class 1
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Degree of protection (NEMA)
Other