Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Number of command positions0
Number of auxiliary contacts as normally closed contact1
With transformerNo
Depth128mm
Number of auxiliary contacts as normally open contact0
Width45mm
Height242mm
Suitable for emergency stopNo
Supporting protocol for DeviceNetNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
With fuseNo
Supporting protocol for INTERBUS-SafetyNo
With short-circuit releaseYes
Supporting protocol for INTERBUSNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for TCP/IPNo
Supporting protocol for other bus systemsYes
Supporting protocol for SERCOSNo
External reset possibleNo
Number of indicator lights0
Supporting protocol for ASINo
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusNo
Rail mounting possibleNo
Release classAdjustable
Supporting protocol for CANNo
Supporting protocol for LONNo
Supporting protocol for EtherNet/IPNo
Degree of protection (NEMA)Other
Ambient temperature, upper operating limit55°C
Supporting protocol for PROFINET CBANo
Temperature compensated overload protectionYes
Coordination class according to IEC 60947-4-3Class 2
Supporting protocol for Foundation FieldbusNo
Rated power, 575 V, 60 Hz, 3-phase0kW
Voltage type for actuatingDC
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Supporting protocol for PROFINET IONo
Rated power, 460 V, 60 Hz, 3-phase0kW
Supporting protocol for SafetyBUS pNo
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Supporting protocol for AS-Interface Safety at WorkNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for DeviceNet SafetyNo
Rated conditional short-circuit current, type 2, 230 V100000A
Rated conditional short-circuit current, type 2, 400 V100000A
Supporting protocol for PROFIsafeNo
Rated operation power at AC-3, 230 V, 3-phase5.5kW
Rated operation power at AC-3, 400 V12.5kW
Rated operation current Ie21.7A
Overload release current setting8 - 32A
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 24V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V25A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user