Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
Depth128mm
Height242mm
With transformerNo
Width45mm
Number of auxiliary contacts as normally closed contact1
Number of indicator lights0
Number of command positions0
Number of auxiliary contacts as normally open contact0
Supporting protocol for LONNo
Suitable for emergency stopNo
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for other bus systemsYes
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for CANNo
Supporting protocol for ASINo
External reset possibleNo
Rail mounting possibleNo
With short-circuit releaseYes
Type of electrical connection of main circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for SERCOSNo
Release classAdjustable
With fuseNo
Supporting protocol for INTERBUS-SafetyNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for SUCONETNo
Rated operation power at AC-3, 230 V, 3-phase7.5kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Voltage type for actuatingDC
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Rated power, 575 V, 60 Hz, 3-phase0kW
Supporting protocol for PROFINET IONo
Temperature compensated overload protectionYes
Supporting protocol for EtherNet/IPNo
Rated conditional short-circuit current, type 2, 230 V100000A
Rated conditional short-circuit current, type 2, 400 V100000A
Ambient temperature, upper operating limit55°C
Degree of protection (NEMA)Other
Coordination class according to IEC 60947-4-3Class 2
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated operation power at AC-3, 400 V15kW
Rated operation current Ie29.3A
Overload release current setting8 - 32A
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 24V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V32A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user