Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue I/O module
  • 1 KOM
  • EATON

Technical specifications

Height90mm
Width35mm
Power consumption1.5W
Depth102mm
Number of HW-interfaces RS-4850
Supporting protocol for LONNo
Suitable for safety functionsNo
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces serial TTY0
Number of HW-interfaces other0
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
Number of HW-interfaces parallel0
Input, currentYes
Supporting protocol for CANNo
Input, thermocoupleNo
Supporting protocol for ASINo
Input, voltageYes
Supporting protocol for SUCONETNo
Supporting protocol for KNXNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Input, resistorNo
Supporting protocol for other bus systemsYes
Input, resistance thermometerNo
Number of HW-interfaces USB0
Output signal configurableYes
Input signal, configurableNo
Output, voltageYes
Output, currentYes
Appendant operation agent (Ex ib)No
Supporting protocol for SERCOSNo
Explosion safety category for gasNone
Type of electric connectionFlat plug-in connection
System accessoryYes
Explosion safety category for dustNone
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP20
Fieldbus connection over separate bus coupler possibleYes
Number of HW-interfaces Wireless0
Appendant operation agent (Ex ia)No
Number of interfaces PROFINET0
Rail mounting possibleYes
Front built-in possibleNo
Wall mounting/direct mountingYes
Performance level according to EN ISO 13849-1None
Rack-assembly possibleNo
IO link masterNo
Radio standard Wi-Fi 802.11No
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Radio standard BluetoothNo
Supporting protocol for EtherNet/IPNo
Radio standard UMTSNo
Supply voltage AC 60 Hz0 - 0V
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
Analogue outputs configurableYes
Radio standard GSMNo
Analogue inputs configurableYes
Supply voltage AC 50 Hz0 - 0V
SIL according to IEC 61508None
Radio standard GPRSNo
Degree of protection (NEMA)1
Supporting protocol for EtherCATNo
Supply voltage DC0 - 0V
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Supporting protocol for PROFIsafeNo
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location class IIINo
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location division 1No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location class IINo
Certified for UL hazardous location class INo
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group G (non-conductive dusts)No
Number of analogue inputs2
Number of analogue outputs2
Voltage type of supply voltageDC
Resolution of the analogue inputs12Bit
Resolution of the analogue outputs12Bit

Related products