Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
With short-circuit release
Yes
Rated control supply voltage Us at AC 60HZ
0 - 0V
Voltage type for actuating
DC
Rated operation power at AC-3, 230 V, 3-phase
0.18kW
Rated control supply voltage Us at AC 50HZ
0 - 0V
Rated operation power at AC-3, 400 V
0.37kW
Rated operation current Ie
1.1A
Number of auxiliary contacts as normally closed contact
1
Number of auxiliary contacts as normally open contact
0
Ambient temperature, upper operating limit
55°C
Rated conditional short-circuit current, type 2, 400 V
100A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Overload release current setting
0.3 - 1.2A
Rated conditional short-circuit current, type 2, 230 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
1.2A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at DC
24 - 24V
Rated power, 575 V, 60 Hz, 3-phase
0kW
Temperature compensated overload protection
Yes
Release class
Adjustable
Number of command positions
0
Type of electrical connection of main circuit
Screw connection
Suitable for emergency stop
No
With transformer
No
With fuse
No
Degree of protection (IP)
IP20
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Coordination class according to IEC 60947-4-3
Class 1
Supporting protocol for CAN
No
External reset possible
No
Number of indicator lights
0
Degree of protection (NEMA)
Other
Supporting protocol for TCP/IP
No
Rail mounting possible
No
Supporting protocol for ASI
No
Supporting protocol for PROFIBUS
No
Supporting protocol for INTERBUS
No
Supporting protocol for Data-Highway
No
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for LON
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes
Supporting protocol for PROFIsafe
No
Width
45mm
Height
198mm
Depth
102mm
From same serie
MSC-DEA-1,2-M7(24VDC)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
With short-circuit release
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Voltage type for actuating
DC
Rated operation power at AC-3, 230 V, 3-phase
0.18kW
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rated operation power at AC-3, 400 V
0.37kW
Rated operation current Ie
1.1A
Number of auxiliary contacts as normally closed contact
1
Number of auxiliary contacts as normally open contact
0
Ambient temperature, upper operating limit
55°C
Rated conditional short-circuit current, type 2, 400 V
100A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Overload release current setting
0.3 .. 1.2A
Rated conditional short-circuit current, type 2, 230 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
1.2A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at DC
24 .. 24V
Rated power, 575 V, 60 Hz, 3-phase
0kW
Temperature compensated overload protection
Release class
Adjustable
Number of command positions
0
Type of electrical connection of main circuit
Screw connection
Suitable for emergency stop
With transformer
With fuse
Degree of protection (IP)
IP20
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Coordination class according to IEC 60947-4-3
Class 1
Supporting protocol for CAN
External reset possible
Number of indicator lights
0
Degree of protection (NEMA)
Other
Supporting protocol for TCP/IP
Rail mounting possible
Supporting protocol for ASI
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for LON
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Supporting protocol for PROFIsafe
Width
45mm
Height
198mm
Depth
102mm
From same serie