Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Rated permanent current Iu
1400A
Version as safety switch
No
Version as reversing switch
No
Number of switches
1
Rated permanent current at AC-23, 400 V
0A
Rated permanent current at AC-21, 400 V
0A
Version as emergency stop installation
Yes
Rated operation power at AC-3, 400 V
0kW
Max. rated operation voltage Ue AC
0V
Version as main switch
Yes
Rated short-time withstand current lcw
34kA
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
Yes
Rated operating voltage
1000 - 1000V
Number of poles
4
Switching power at 400 V
0kW
Voltage release optional
Yes
Device construction
Built-in device fixed built-in technique
Conditioned rated short-circuit current Iq
0kA
Type of control element
Rocker lever
Suitable for front mounting 4-hole
No
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Screw connection
Suitable for floor mounting
Yes
Colour control element
Black
Version as maintenance-/service switch
Yes
With pre-assembled cabling
No
Degree of protection (IP), front side
IP20
Motor drive integrated
No
Suitable for front mounting centre
No
Rated operation power at AC-23, 400 V
0kW
Degree of protection (NEMA)
Other
Suitable for intermediate mounting
Yes
Interlockable
Yes
Suitable for distribution board installation
Yes
Width
280mm
Depth
401mm
Height
207mm
Related products
N4-4-1400-S1-DC

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Rated permanent current Iu
1400A
Version as safety switch
Version as reversing switch
Number of switches
1
Rated permanent current at AC-23, 400 V
0A
Rated permanent current at AC-21, 400 V
0A
Version as emergency stop installation
Rated operation power at AC-3, 400 V
0kW
Max. rated operation voltage Ue AC
0V
Version as main switch
Rated short-time withstand current lcw
34kA
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
Rated operating voltage
1000 .. 1000V
Number of poles
4
Switching power at 400 V
0kW
Voltage release optional
Device construction
Built-in device fixed built-in technique
Conditioned rated short-circuit current Iq
0kA
Type of control element
Rocker lever
Suitable for front mounting 4-hole
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Screw connection
Suitable for floor mounting
Colour control element
Black
Version as maintenance-/service switch
With pre-assembled cabling
Degree of protection (IP), front side
IP20
Motor drive integrated
Suitable for front mounting centre
Rated operation power at AC-23, 400 V
0kW
Degree of protection (NEMA)
Other
Suitable for intermediate mounting
Interlockable
Suitable for distribution board installation
Width
280mm
Depth
401mm
Height
207mm