  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 4 KOM
  • EATON

Technical specifications

Number of digital inputs0
Suitable for safety functionsNo
Height39mm
Number of digital outputs1
Width54mm
Time delay at signal exchange10 - 84ms
Input current at signal 10mA
Depth81mm
Number of HW-interfaces RS-2320
Voltage type of supply voltageDC
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4850
Number of HW-interfaces other2
Supporting protocol for CANNo
Supporting protocol for PROFIBUSNo
Output current0.5A
Supporting protocol for TCP/IPNo
Supporting protocol for other bus systemsYes
Supporting protocol for KNXNo
Supporting protocol for SUCONETNo
Short-circuit protection, outputs availableNo
Number of HW-interfaces industrial Ethernet0
Supporting protocol for LONNo
Supporting protocol for Data-HighwayNo
Number of HW-interfaces USB0
Supporting protocol for INTERBUSNo
Type of voltage (input voltage)DC
Supporting protocol for ModbusNo
Number of HW-interfaces RS-4220
With optical interfaceNo
Supporting protocol for DeviceNetNo
Supporting protocol for ASINo
Type of electric connectionSpring clamp connection
Rail mounting possibleNo
System accessoryYes
Appendant operation agent (Ex ia)No
Radio standard BluetoothNo
Fieldbus connection over separate bus coupler possibleYes
Explosion safety category for gasNone
Degree of protection (IP)IP20
Performance level according to EN ISO 13849-1None
Wall mounting/direct mountingNo
Supporting protocol for AS-Interface Safety at WorkNo
Appendant operation agent (Ex ib)No
Type of digital outputOther
Front built-in possibleNo
Supporting protocol for Foundation FieldbusNo
IO link masterNo
Supporting protocol for INTERBUS-SafetyNo
Radio standard Wi-Fi 802.11No
Supporting protocol for DeviceNet SafetyNo
Rack-assembly possibleNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SERCOSNo
Number of HW-interfaces Wireless0
Number of interfaces PROFINET0
Explosion safety category for dustNone
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Radio standard GSMNo
Permitted voltage at output20.4 - 28.8V
Certified for UL hazardous location division 2No
Radio standard GPRSNo
Supporting protocol for EtherCATNo
Certified for UL hazardous location class INo
Digital inputs configurableNo
Certified for UL hazardous location group A (acetylene)No
Type of output voltageDC
Certified for UL hazardous location division 1No
Digital outputs configurableNo
SIL according to IEC 61508None
Certified for UL hazardous location class IIINo
Supply voltage AC 60 Hz0 - 0V
Certified for UL hazardous location group B (hydrogen)No
Permitted voltage at input15 - 15V
Radio standard UMTSNo
Supply voltage DC15 - 15V
Supply voltage AC 50 Hz0 - 0V
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location class IINo
Supporting protocol for PROFIsafeNo
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group E (metal dusts)No
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PKE-SWD-32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 4 KOM
  • EATON

Technical specifications

Number of digital inputs

0

Suitable for safety functions

Height

39mm

Number of digital outputs

1

Width

54mm

Time delay at signal exchange

10 .. 84ms

Input current at signal 1

0mA

Depth

81mm

Number of HW-interfaces RS-232

0

Voltage type of supply voltage

DC

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces other

2

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Output current

0.5A

Supporting protocol for TCP/IP

Supporting protocol for other bus systems

Supporting protocol for KNX

Supporting protocol for SUCONET

Short-circuit protection, outputs available

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for LON

Supporting protocol for Data-Highway

Number of HW-interfaces USB

0

Supporting protocol for INTERBUS

Type of voltage (input voltage)

DC

Supporting protocol for Modbus

Number of HW-interfaces RS-422

0

With optical interface

Supporting protocol for DeviceNet

Supporting protocol for ASI

Type of electric connection

Spring clamp connection

Rail mounting possible

System accessory

Appendant operation agent (Ex ia)

Radio standard Bluetooth

Fieldbus connection over separate bus coupler possible

Explosion safety category for gas

None

Degree of protection (IP)

IP20

Performance level according to EN ISO 13849-1

None

Wall mounting/direct mounting

Supporting protocol for AS-Interface Safety at Work

Appendant operation agent (Ex ib)

Type of digital output

Other

Front built-in possible

Supporting protocol for Foundation Fieldbus

IO link master

Supporting protocol for INTERBUS-Safety

Radio standard Wi-Fi 802.11

Supporting protocol for DeviceNet Safety

Rack-assembly possible

Supporting protocol for EtherNet/IP

Supporting protocol for SERCOS

Number of HW-interfaces Wireless

0

Number of interfaces PROFINET

0

Explosion safety category for dust

None

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Radio standard GSM

Permitted voltage at output

20.4 .. 28.8V

Certified for UL hazardous location division 2

Radio standard GPRS

Supporting protocol for EtherCAT

Certified for UL hazardous location class I

Digital inputs configurable

Certified for UL hazardous location group A (acetylene)

Type of output voltage

DC

Certified for UL hazardous location division 1

Digital outputs configurable

SIL according to IEC 61508

None

Certified for UL hazardous location class III

Supply voltage AC 60 Hz

0 .. 0V

Certified for UL hazardous location group B (hydrogen)

Permitted voltage at input

15 .. 15V

Radio standard UMTS

Supply voltage DC

15 .. 15V

Supply voltage AC 50 Hz

0 .. 0V

Certified for UL hazardous location group C (ethylene)

Certified for UL hazardous location class II

Supporting protocol for PROFIsafe

Certified for UL hazardous location group D (propane)

Certified for UL hazardous location group F (carbonaceous dusts)

Certified for UL hazardous location group G (non-conductive dusts)

Certified for UL hazardous location group E (metal dusts)

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.