Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Rated permanent current Iu250A
Integrated earth fault protectionNo
Number of auxiliary contacts as normally closed contact0
Rated voltage690 - 690V
Overload release current setting125 - 250A
Device constructionBuilt-in device plug-in technique
DIN rail (top hat rail) mounting optionalYes
Type of electrical connection of main circuitScrew connection
Adjustment range short-term delayed short-circuit release250 - 2500A
Adjustment range undelayed short-circuit release3000 - 3000A
Motor drive optionalYes
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
Type of control elementRocker lever
Number of poles4
Degree of protection (IP)IP20
Complete device with protection unitYes
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Motor drive integratedNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-4-VE250/160-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Rated permanent current Iu

250A

Integrated earth fault protection

Number of auxiliary contacts as normally closed contact

0

Rated voltage

690 .. 690V

Overload release current setting

125 .. 250A

Device construction

Built-in device plug-in technique

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Screw connection

Adjustment range short-term delayed short-circuit release

250 .. 2500A

Adjustment range undelayed short-circuit release

3000 .. 3000A

Motor drive optional

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Number of poles

4

Degree of protection (IP)

IP20

Complete device with protection unit

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Motor drive integrated

Related products