Aleta.hr

Details

  • Sensors
  • Inductive proximity switch
  • 1 KOM
  • EATON

Technical specifications

Material housingPlastic
CascadableNo
Voltage typeDC
Suitable for safety functionsNo
Switching frequency500Hz
Coating housingOther
Rated control supply voltage Us at AC 60HZ0 - 0V
Number of semiconductor outputs with signalling function1
Rated control supply voltage Us at DC10 - 30V
Number of contact energized outputs with signalling function0
Type of switch functionNormally open contact
Number of protected contact energized outputs0
Type of electric connectionCable
Switching distance8mm
Number of protected semiconductor outputs0
Rated control supply voltage Us at AC 50HZ0 - 0V
Type of interface for safety communicationNone
Type of switching outputNPN
Explosion safety category for dustNone
Explosion safety category for gasNone
Compression-resistantNo
Mechanical mounting condition for sensorNot flat
Max. output current at protected output0mA
Diameter sensor18mm
Type of actuationMetallic Target
Construction type housingCylinder, screw-thread
SIL according to IEC 61508None
Degree of protection (NEMA)4X, 13
Height of sensor0mm
With monitoring function downstream switching devicesNo
Width sensor0mm
Performance level according to EN ISO 13849-1None
Supply voltage10 - 30V
Length of sensor55mm
Type of interfaceNone

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

E55CAL18T110E

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • Inductive proximity switch
  • 1 KOM
  • EATON

Technical specifications

Material housing

Plastic

Cascadable

Voltage type

DC

Suitable for safety functions

Switching frequency

500Hz

Coating housing

Other

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Number of semiconductor outputs with signalling function

1

Rated control supply voltage Us at DC

10 .. 30V

Number of contact energized outputs with signalling function

0

Type of switch function

Normally open contact

Number of protected contact energized outputs

0

Type of electric connection

Cable

Switching distance

8mm

Number of protected semiconductor outputs

0

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Type of interface for safety communication

None

Type of switching output

NPN

Explosion safety category for dust

None

Explosion safety category for gas

None

Compression-resistant

Mechanical mounting condition for sensor

Not flat

Max. output current at protected output

0mA

Diameter sensor

18mm

Type of actuation

Metallic Target

Construction type housing

Cylinder, screw-thread

SIL according to IEC 61508

None

Degree of protection (NEMA)

4X, 13

Height of sensor

0mm

With monitoring function downstream switching devices

Width sensor

0mm

Performance level according to EN ISO 13849-1

None

Supply voltage

10 .. 30V

Length of sensor

55mm

Type of interface

None

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.