Aleta.hr
Main Product Image

E58-18DP100-HDP

Code: 1201918

ManufacturerEaton
Catalog number135665
EAN code4015081324583

Details

  • Sensors
  • Light scanner with background masking
  • 1 KOM
  • EATON

Technical specifications

Voltage typeDC
Suitable for safety functionsNo
Material housingMetal
Ambient temperature-40 - 55°C
Number of protected contact energized outputs0
Number of semiconductor outputs with signalling function2
Rated control supply voltage Us at DC10 - 30V
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs0
Rated control supply voltage Us at AC 50HZ0 - 0V
Type of interface for safety communicationOther
Switching frequency500Hz
Type of electric connectionConnector M12
Explosion safety category for gasNone
Type of switch functionOther
Operation agent-safety classSafety class 2
Type of lightOther
Setting procedureOther
Rated control supply voltage Us at AC 60HZ0 - 0V
Construction type housingCylinder, screw-thread
Explosion safety category for dustNone
Laser protection classNone
Type of switching outputPNP
With time functionNo
Light dot0mm²
Max. output current at protected output0mA
Min. reflector distance0mm
With monitoring function downstream switching devicesNo
With restart blockageNo
Pre failure noticeNo
Height of sensor0mm
With communication interface AS-InterfaceNo
Response time1ms
AWG-number0
Analogue output 0 V ... 10 VNo
With communication interface analogueNo
Analogue output 4 mA ... 20 mANo
Transmission range of the safety field0m
Material of cable sheathOther
Material of optical surfaceGlass
With communication interface CANOpenNo
Type of safety according to IEC 61496-11
Wavelength of the sensor660nm
Analogue output -10 V ... +10 VNo
Width sensor0mm
Switching voltage of OSSD at state "high"30V
Analogue output 0 mA ... 20 mANo
Diameter sensor18mm
With communication interface EthernetNo
With communication interface DeviceNetNo
With communication interface INTERBUSNo
With communication interface RS-422No
With communication interface RS-232No
With communication interface PROFIBUSNo
With other analogue outputNo
Length of sensor80mm
Sensing modeDark switching
Degree of protection (NEMA)6
With communication interface RS-485No
With communication interface SSINo
With communication interface SSDNo
With reflectorNo
Max. output current250mA
Adjustment range0 - 100mm
Operating distance0 - 0mm
Degree of protection (IP)IP68
Max. switching distance127mm
Rated switching distance100mm
TriangulationBackground fade-out

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

E58-18DP100-HDP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • Light scanner with background masking
  • 1 KOM
  • EATON

Technical specifications

Voltage type

DC

Suitable for safety functions

Material housing

Metal

Ambient temperature

-40 .. 55°C

Number of protected contact energized outputs

0

Number of semiconductor outputs with signalling function

2

Rated control supply voltage Us at DC

10 .. 30V

Number of contact energized outputs with signalling function

0

Number of protected semiconductor outputs

0

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Type of interface for safety communication

Other

Switching frequency

500Hz

Type of electric connection

Connector M12

Explosion safety category for gas

None

Type of switch function

Other

Operation agent-safety class

Safety class 2

Type of light

Other

Setting procedure

Other

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Construction type housing

Cylinder, screw-thread

Explosion safety category for dust

None

Laser protection class

None

Type of switching output

PNP

With time function

Light dot

0mm²

Max. output current at protected output

0mA

Min. reflector distance

0mm

With monitoring function downstream switching devices

With restart blockage

Pre failure notice

Height of sensor

0mm

With communication interface AS-Interface

Response time

1ms

AWG-number

0

Analogue output 0 V ... 10 V

With communication interface analogue

Analogue output 4 mA ... 20 mA

Transmission range of the safety field

0m

Material of cable sheath

Other

Material of optical surface

Glass

With communication interface CANOpen

Type of safety according to IEC 61496-1

1

Wavelength of the sensor

660nm

Analogue output -10 V ... +10 V

Width sensor

0mm

Switching voltage of OSSD at state "high"

30V

Analogue output 0 mA ... 20 mA

Diameter sensor

18mm

With communication interface Ethernet

With communication interface DeviceNet

With communication interface INTERBUS

With communication interface RS-422

With communication interface RS-232

With communication interface PROFIBUS

With other analogue output

Length of sensor

80mm

Sensing mode

Dark switching

Degree of protection (NEMA)

6

With communication interface RS-485

With communication interface SSI

With communication interface SSD

With reflector

Max. output current

250mA

Adjustment range

0 .. 100mm

Operating distance

0 .. 0mm

Degree of protection (IP)

IP68

Max. switching distance

127mm

Rated switching distance

100mm

Triangulation

Background fade-out

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.