Technical specifications

Material housingMetal
Voltage typeDC
Max. output current250mA
With time functionNo
Suitable for safety functionsNo
Switching frequency500Hz
Adjustment range0 - 50mm
Ambient temperature-40 - 55°C
Operation agent-safety classSafety class 2
Type of electric connectionCable
Number of contact energized outputs with signalling function0
Construction type housingCylinder, screw-thread
Number of protected contact energized outputs0
Type of lightOther
Max. output current at protected output0mA
Type of switching outputNPN
Rated control supply voltage Us at DC10 - 30V
Number of semiconductor outputs with signalling function2
Explosion safety category for gasNone
Number of protected semiconductor outputs0
Rated control supply voltage Us at AC 60HZ0 - 0V
Explosion safety category for dustNone
Laser protection classNone
Setting procedureOther
Rated control supply voltage Us at AC 50HZ0 - 0V
Light dot0mm²
Type of switch functionOther
Response time1ms
Transmission range of the safety field0m
With monitoring function downstream switching devicesNo
Min. reflector distance0mm
With restart blockageNo
Type of interface for safety communicationOther
With communication interface DeviceNetNo
Type of safety according to IEC 61496-11
Wavelength of the sensor660nm
Width sensor0mm
Diameter sensor18mm
Analogue output 0 mA ... 20 mANo
With communication interface CANOpenNo
Degree of protection (IP)IP68
Switching voltage of OSSD at state "high"30V
Operating distance0 - 0mm
Analogue output 0 V ... 10 VNo
Analogue output 4 mA ... 20 mANo
With communication interface AS-InterfaceNo
AWG-number22
Pre failure noticeNo
With communication interface analogueNo
Height of sensor0mm
Analogue output -10 V ... +10 VNo
Material of cable sheathPolyvinyl chloride (PVC)
With communication interface INTERBUSNo
With communication interface EthernetNo
With communication interface PROFIBUSNo
With communication interface RS-422No
With communication interface RS-232No
Material of optical surfaceGlass
With reflectorNo
Degree of protection (NEMA)6
With communication interface SSINo
TriangulationBackground fade-out
Length of sensor80mm
With other analogue outputNo
With communication interface SSDNo
With communication interface RS-485No
Rated switching distance50mm
Sensing modeLight switching
Max. switching distance57mm

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

E58-18DP50-HL

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • Light scanner with background masking
  • 1 KOM
  • EATON

Technical specifications

Material housing

Metal

Voltage type

DC

Max. output current

250mA

With time function

Suitable for safety functions

Switching frequency

500Hz

Adjustment range

0 .. 50mm

Ambient temperature

-40 .. 55°C

Operation agent-safety class

Safety class 2

Type of electric connection

Cable

Number of contact energized outputs with signalling function

0

Construction type housing

Cylinder, screw-thread

Number of protected contact energized outputs

0

Type of light

Other

Max. output current at protected output

0mA

Type of switching output

NPN

Rated control supply voltage Us at DC

10 .. 30V

Number of semiconductor outputs with signalling function

2

Explosion safety category for gas

None

Number of protected semiconductor outputs

0

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Explosion safety category for dust

None

Laser protection class

None

Setting procedure

Other

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Light dot

0mm²

Type of switch function

Other

Response time

1ms

Transmission range of the safety field

0m

With monitoring function downstream switching devices

Min. reflector distance

0mm

With restart blockage

Type of interface for safety communication

Other

With communication interface DeviceNet

Type of safety according to IEC 61496-1

1

Wavelength of the sensor

660nm

Width sensor

0mm

Diameter sensor

18mm

Analogue output 0 mA ... 20 mA

With communication interface CANOpen

Degree of protection (IP)

IP68

Switching voltage of OSSD at state "high"

30V

Operating distance

0 .. 0mm

Analogue output 0 V ... 10 V

Analogue output 4 mA ... 20 mA

With communication interface AS-Interface

AWG-number

22

Pre failure notice

With communication interface analogue

Height of sensor

0mm

Analogue output -10 V ... +10 V

Material of cable sheath

Polyvinyl chloride (PVC)

With communication interface INTERBUS

With communication interface Ethernet

With communication interface PROFIBUS

With communication interface RS-422

With communication interface RS-232

Material of optical surface

Glass

With reflector

Degree of protection (NEMA)

6

With communication interface SSI

Triangulation

Background fade-out

Length of sensor

80mm

With other analogue output

With communication interface SSD

With communication interface RS-485

Rated switching distance

50mm

Sensing mode

Light switching

Max. switching distance

57mm

Related products