Aleta.hr

Details

  • Sensors
  • Light scanner with background masking
  • 1 KOM
  • EATON

Technical specifications

Max. output current100mA
Material housingMetal
Voltage typeDC
Suitable for safety functionsNo
Number of semiconductor outputs with signalling function2
Number of protected semiconductor outputs0
Number of contact energized outputs with signalling function0
Number of protected contact energized outputs0
Type of switching outputPNP/NPN
With time functionNo
Setting procedureOther
Ambient temperature-40 - 55°C
Rated control supply voltage Us at DC10 - 30V
Type of switch functionOther
Operation agent-safety classSafety class 2
Rated control supply voltage Us at AC 50HZ0 - 0V
Rated control supply voltage Us at AC 60HZ0 - 0V
Explosion safety category for gasNone
Switching frequency312Hz
Type of interface for safety communicationOther
Adjustment range0 - 280mm
Type of electric connectionConnector M12
Light dot0mm²
Max. output current at protected output0mA
Explosion safety category for dustNone
Construction type housingCylinder, screw-thread
Min. reflector distance0mm
Type of lightOther
Laser protection classNone
Analogue output 0 mA ... 20 mANo
Operating distance0 - 0mm
Type of safety according to IEC 61496-11
With restart blockageNo
Analogue output -10 V ... +10 VNo
Wavelength of the sensor660nm
Transmission range of the safety field0m
Degree of protection (IP)IP68
Response time1.6ms
Pre failure noticeNo
With monitoring function downstream switching devicesNo
Analogue output 4 mA ... 20 mANo
Material of cable sheathOther
AWG-number0
Switching voltage of OSSD at state "high"30V
Width sensor0mm
Diameter sensor30mm
Material of optical surfaceGlass
Analogue output 0 V ... 10 VNo
With communication interface EthernetNo
With communication interface analogueNo
With communication interface CANOpenNo
With communication interface AS-InterfaceNo
Height of sensor0mm
With communication interface DeviceNetNo
Degree of protection (NEMA)6
With communication interface RS-422No
With communication interface INTERBUSNo
With communication interface SSDNo
With communication interface PROFIBUSNo
Rated switching distance280mm
Length of sensor111mm
With other analogue outputNo
With communication interface SSINo
With communication interface RS-232No
With reflectorNo
With communication interface RS-485No
Sensing modeLight switching
TriangulationBackground fade-out
Max. switching distance318mm

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

E58-30DPS280-HLP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • Light scanner with background masking
  • 1 KOM
  • EATON

Technical specifications

Max. output current

100mA

Material housing

Metal

Voltage type

DC

Suitable for safety functions

Number of semiconductor outputs with signalling function

2

Number of protected semiconductor outputs

0

Number of contact energized outputs with signalling function

0

Number of protected contact energized outputs

0

Type of switching output

PNP/NPN

With time function

Setting procedure

Other

Ambient temperature

-40 .. 55°C

Rated control supply voltage Us at DC

10 .. 30V

Type of switch function

Other

Operation agent-safety class

Safety class 2

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Explosion safety category for gas

None

Switching frequency

312Hz

Type of interface for safety communication

Other

Adjustment range

0 .. 280mm

Type of electric connection

Connector M12

Light dot

0mm²

Max. output current at protected output

0mA

Explosion safety category for dust

None

Construction type housing

Cylinder, screw-thread

Min. reflector distance

0mm

Type of light

Other

Laser protection class

None

Analogue output 0 mA ... 20 mA

Operating distance

0 .. 0mm

Type of safety according to IEC 61496-1

1

With restart blockage

Analogue output -10 V ... +10 V

Wavelength of the sensor

660nm

Transmission range of the safety field

0m

Degree of protection (IP)

IP68

Response time

1.6ms

Pre failure notice

With monitoring function downstream switching devices

Analogue output 4 mA ... 20 mA

Material of cable sheath

Other

AWG-number

0

Switching voltage of OSSD at state "high"

30V

Width sensor

0mm

Diameter sensor

30mm

Material of optical surface

Glass

Analogue output 0 V ... 10 V

With communication interface Ethernet

With communication interface analogue

With communication interface CANOpen

With communication interface AS-Interface

Height of sensor

0mm

With communication interface DeviceNet

Degree of protection (NEMA)

6

With communication interface RS-422

With communication interface INTERBUS

With communication interface SSD

With communication interface PROFIBUS

Rated switching distance

280mm

Length of sensor

111mm

With other analogue output

With communication interface SSI

With communication interface RS-232

With reflector

With communication interface RS-485

Sensing mode

Light switching

Triangulation

Background fade-out

Max. switching distance

318mm

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.