Aleta.hr

Details

  • Sensors
  • Light scanner with background masking
  • 1 KOM
  • EATON

Technical specifications

Suitable for safety functionsNo
Voltage typeDC
Max. output current100mA
Number of semiconductor outputs with signalling function1
Ambient temperature-25 - 55°C
Switching frequency500Hz
Adjustment range0 - 100mm
Number of protected semiconductor outputs0
Material housingPlastic
With time functionNo
Number of contact energized outputs with signalling function0
Number of protected contact energized outputs0
Type of electric connectionConnector M12
Type of interface for safety communicationOther
Explosion safety category for dustNone
Type of switch functionOther
Laser protection classNone
Setting procedureOther
Construction type housingCuboid
Rated control supply voltage Us at DC10 - 30V
Type of switching outputNPN
Rated control supply voltage Us at AC 60HZ0 - 0V
Explosion safety category for gasNone
Rated control supply voltage Us at AC 50HZ0 - 0V
Operation agent-safety classSafety class 2
Max. output current at protected output100mA
Light dot0mm²
Type of lightOther
With monitoring function downstream switching devicesNo
Min. reflector distance0mm
Response time1ms
Type of safety according to IEC 61496-11
With restart blockageNo
Transmission range of the safety field0m
Switching voltage of OSSD at state "high"30V
Operating distance0 - 0mm
Material of optical surfacePlastic
Wavelength of the sensor660nm
Pre failure noticeNo
Analogue output 0 V ... 10 VNo
Analogue output -10 V ... +10 VNo
Material of cable sheathOther
Width sensor33mm
AWG-number0
Analogue output 0 mA ... 20 mANo
Diameter sensor0mm
Degree of protection (IP)IP68
Height of sensor55mm
With communication interface analogueNo
Analogue output 4 mA ... 20 mANo
With communication interface DeviceNetNo
With communication interface CANOpenNo
With communication interface EthernetNo
With communication interface RS-485No
With communication interface RS-422No
With communication interface AS-InterfaceNo
With communication interface INTERBUSNo
With communication interface RS-232No
With communication interface SSDNo
With communication interface PROFIBUSNo
Max. switching distance100mm
Length of sensor41mm
With reflectorNo
With communication interface SSINo
TriangulationBackground fade-out
With other analogue outputNo
Sensing modeLight switching
Degree of protection (NEMA)6
Rated switching distance100mm

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

E65-SMPP100-HLD

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • Light scanner with background masking
  • 1 KOM
  • EATON

Technical specifications

Suitable for safety functions

Voltage type

DC

Max. output current

100mA

Number of semiconductor outputs with signalling function

1

Ambient temperature

-25 .. 55°C

Switching frequency

500Hz

Adjustment range

0 .. 100mm

Number of protected semiconductor outputs

0

Material housing

Plastic

With time function

Number of contact energized outputs with signalling function

0

Number of protected contact energized outputs

0

Type of electric connection

Connector M12

Type of interface for safety communication

Other

Explosion safety category for dust

None

Type of switch function

Other

Laser protection class

None

Setting procedure

Other

Construction type housing

Cuboid

Rated control supply voltage Us at DC

10 .. 30V

Type of switching output

NPN

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Explosion safety category for gas

None

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Operation agent-safety class

Safety class 2

Max. output current at protected output

100mA

Light dot

0mm²

Type of light

Other

With monitoring function downstream switching devices

Min. reflector distance

0mm

Response time

1ms

Type of safety according to IEC 61496-1

1

With restart blockage

Transmission range of the safety field

0m

Switching voltage of OSSD at state "high"

30V

Operating distance

0 .. 0mm

Material of optical surface

Plastic

Wavelength of the sensor

660nm

Pre failure notice

Analogue output 0 V ... 10 V

Analogue output -10 V ... +10 V

Material of cable sheath

Other

Width sensor

33mm

AWG-number

0

Analogue output 0 mA ... 20 mA

Diameter sensor

0mm

Degree of protection (IP)

IP68

Height of sensor

55mm

With communication interface analogue

Analogue output 4 mA ... 20 mA

With communication interface DeviceNet

With communication interface CANOpen

With communication interface Ethernet

With communication interface RS-485

With communication interface RS-422

With communication interface AS-Interface

With communication interface INTERBUS

With communication interface RS-232

With communication interface SSD

With communication interface PROFIBUS

Max. switching distance

100mm

Length of sensor

41mm

With reflector

With communication interface SSI

Triangulation

Background fade-out

With other analogue output

Sensing mode

Light switching

Degree of protection (NEMA)

6

Rated switching distance

100mm

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.