- Low-voltage industrial components
- Combination of contactors
- 1 KOM
- EATON
Technical specifications
Rail mounting possible
No
Rated control supply voltage Us at AC 50HZ
230 - 230V
Rated control supply voltage Us at DC
0 - 0V
Function
Reversing contactor
Voltage type (operating voltage)
AC
Degree of protection (NEMA)
Other
Operating voltage at DC
0 - 0V
Operating voltage at AC 50 Hz
24 - 690V
Rated control supply voltage Us at AC 60HZ
240 - 240V
Height
68mm
Number of normally open contacts as main contact
6
Number of normally closed contacts as main contact
0
Width
90mm
Type of electrical connection of main circuit
Screw connection
Voltage type for actuating
AC
Depth
117mm
Number of auxiliary contacts as change-over contact
0
Operating voltage at AC 60 Hz
24 - 690V
Number of auxiliary contacts as normally closed contact
0
Rated operation current Ie at AC-1, 400 V
12A
Rated operation power at AC-3, 400 V
5.5kW
Number of auxiliary contacts as normally open contact
2
Rated operation power NEMA
7.4kW
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rated operation current Ie at AC-3, 400 V
12A
Degree of protection (IP)
IP20
Related products
From same serie
DIULM12/21(230V50HZ,240V60HZ)

Details
- Low-voltage industrial components
- Combination of contactors
- 1 KOM
- EATON
Technical specifications
Rail mounting possible
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Rated control supply voltage Us at DC
0 .. 0V
Function
Reversing contactor
Voltage type (operating voltage)
AC
Degree of protection (NEMA)
Other
Operating voltage at DC
0 .. 0V
Operating voltage at AC 50 Hz
24 .. 690V
Rated control supply voltage Us at AC 60HZ
240 .. 240V
Height
68mm
Number of normally open contacts as main contact
6
Number of normally closed contacts as main contact
0
Width
90mm
Type of electrical connection of main circuit
Screw connection
Voltage type for actuating
AC
Depth
117mm
Number of auxiliary contacts as change-over contact
0
Operating voltage at AC 60 Hz
24 .. 690V
Number of auxiliary contacts as normally closed contact
0
Rated operation current Ie at AC-1, 400 V
12A
Rated operation power at AC-3, 400 V
5.5kW
Number of auxiliary contacts as normally open contact
2
Rated operation power NEMA
7.4kW
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rated operation current Ie at AC-3, 400 V
12A
Degree of protection (IP)
IP20