Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Combined arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Max. continuous voltage AC280V
Voltage protection level1.3kV
Number of poles-
Remote signallingNo
Construction size1 modular spacing
Follow current extinguishing capability-kA
Lightning impulse current (10/350 µs)12.5kA
Max. continuous voltage DC300V
Degree of protection (IP)IP20
Voltage protection level L-N1.3kV
Max. PV-voltage-V
Nominal voltage DC-V
Nominal voltage AC-V
Energy-coordinated protection effect with regard to the terminal equipmentNo
Voltage protection level (DC+ - DC-)-kV
Voltage protection level N-PE-kV
System configuration TTNo
System configuration TN-SNo
Max. conductor cross section flexible (fine-strand)-mm²
System configuration ITNo
Specific energy (W/R)-kJ/Ohm
System configuration DCNo
Voltage protection level L-PE-kV
Max. conductor cross section solid (solid, stranded)35mm²
Voltage protection level (DC+/DC- - PE)-kV
System configuration TNNo
System configuration TN-CNo
System configuration TN-C-SNo
System configuration otherNo
Integrated backup fuseNo
Max. overcurrent protection device, parallel connection (fuse)-A
Overcurrent protected voltage tappingNo
Max. overcurrent protection device, series connection (fuse)-A
Voltage switching spark gap technologyNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

5093726 | V50-B+C 0-300PV

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Combined arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Max. continuous voltage AC

280V

Voltage protection level

1.3kV

Number of poles

-

Remote signalling

Construction size

1 modular spacing

Follow current extinguishing capability

-kA

Lightning impulse current (10/350 µs)

12.5kA

Max. continuous voltage DC

300V

Degree of protection (IP)

IP20

Voltage protection level L-N

1.3kV

Max. PV-voltage

-V

Nominal voltage DC

-V

Nominal voltage AC

-V

Energy-coordinated protection effect with regard to the terminal equipment

Voltage protection level (DC+ - DC-)

-kV

Voltage protection level N-PE

-kV

System configuration TT

System configuration TN-S

Max. conductor cross section flexible (fine-strand)

-mm²

System configuration IT

Specific energy (W/R)

-kJ/Ohm

System configuration DC

Voltage protection level L-PE

-kV

Max. conductor cross section solid (solid, stranded)

35mm²

Voltage protection level (DC+/DC- - PE)

-kV

System configuration TN

System configuration TN-C

System configuration TN-C-S

System configuration other

Integrated backup fuse

Max. overcurrent protection device, parallel connection (fuse)

-A

Overcurrent protected voltage tapping

Max. overcurrent protection device, series connection (fuse)

-A

Voltage switching spark gap technology

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.