Technical specifications
Suitable for floor mounting
No
Suitable for intermediate mounting
No
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Number of switches
-
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Version as maintenance-/service switch
Yes
Version as main switch
Yes
Rated short-time withstand current lcw
0.5kA
Switching power at 400 V
11kW
Rated permanent current at AC-21, 400 V
40A
Rated operation power at AC-23, 400 V
11kW
Device construction
Built-in device fixed built-in technique
Version as safety switch
No
Suitable for front mounting centre
No
Max. rated operation voltage Ue AC
750V
Rated operating voltage
750 - 750V
Version as emergency stop installation
No
Rated permanent current at AC-23, 400 V
23A
Type of electrical connection of main circuit
Screw connection
Number of poles
4
Motor drive optional
No
Version as reversing switch
No
Rated permanent current Iu
40A
Voltage release optional
No
Suitable for front mounting 4-hole
No
Interlockable
No
Motor drive integrated
No
Type of control element
None
Suitable for distribution board installation
Yes
Degree of protection (NEMA)
1
Degree of protection (IP), front side
IP20
From same serie
1SCA104956R1001 | OT40FT4N2

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Suitable for floor mounting
Suitable for intermediate mounting
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Number of switches
-
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Version as maintenance-/service switch
Version as main switch
Rated short-time withstand current lcw
0.5kA
Switching power at 400 V
11kW
Rated permanent current at AC-21, 400 V
40A
Rated operation power at AC-23, 400 V
11kW
Device construction
Built-in device fixed built-in technique
Version as safety switch
Suitable for front mounting centre
Max. rated operation voltage Ue AC
750V
Rated operating voltage
750 .. 750V
Version as emergency stop installation
Rated permanent current at AC-23, 400 V
23A
Type of electrical connection of main circuit
Screw connection
Number of poles
4
Motor drive optional
Version as reversing switch
Rated permanent current Iu
40A
Voltage release optional
Suitable for front mounting 4-hole
Interlockable
Motor drive integrated
Type of control element
None
Suitable for distribution board installation
Degree of protection (NEMA)
1
Degree of protection (IP), front side
IP20