Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Suitable for floor mounting
No
Suitable for intermediate mounting
No
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Number of switches
-
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Version as main switch
Yes
Max. rated operation voltage Ue AC
750V
Version as emergency stop installation
No
Rated permanent current Iu
63A
Rated operating voltage
750 - 750V
Version as safety switch
No
Rated operation power at AC-23, 400 V
22kW
Version as maintenance-/service switch
Yes
Rated permanent current at AC-23, 400 V
63A
Rated short-time withstand current lcw
1kA
Switching power at 400 V
22kW
Rated permanent current at AC-21, 400 V
63A
Number of poles
6
Motor drive optional
No
Motor drive integrated
No
Voltage release optional
No
Device construction
Built-in device fixed built-in technique
Suitable for front mounting centre
No
Suitable for distribution board installation
Yes
Suitable for front mounting 4-hole
No
Interlockable
No
Version as reversing switch
No
Type of control element
Short thumb-grip
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP20
Degree of protection (NEMA)
1
1SCA105379R1001 | OT63F6

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Suitable for floor mounting
Suitable for intermediate mounting
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Number of switches
-
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Version as main switch
Max. rated operation voltage Ue AC
750V
Version as emergency stop installation
Rated permanent current Iu
63A
Rated operating voltage
750 .. 750V
Version as safety switch
Rated operation power at AC-23, 400 V
22kW
Version as maintenance-/service switch
Rated permanent current at AC-23, 400 V
63A
Rated short-time withstand current lcw
1kA
Switching power at 400 V
22kW
Rated permanent current at AC-21, 400 V
63A
Number of poles
6
Motor drive optional
Motor drive integrated
Voltage release optional
Device construction
Built-in device fixed built-in technique
Suitable for front mounting centre
Suitable for distribution board installation
Suitable for front mounting 4-hole
Interlockable
Version as reversing switch
Type of control element
Short thumb-grip
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP20
Degree of protection (NEMA)
1