1SDA054034R1 | T4S 250 PR221DS-LS IN=160 4P F F

Code: 1526133

ManufacturerABB
Catalog number1SDA054034R1
EAN code8015644551261

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With under voltage releaseNo
Overload release current setting64.0 - 160A
Type of electrical connection of main circuitBolt connection
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
Number of poles4
Motor drive integratedNo
Complete device with protection unitYes
Rated permanent current Iu250A
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally open contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range undelayed short-circuit release160 - 1600A
With switched-off indicatorNo
Integrated earth fault protectionNo
Position of connection for main current circuitFront side
Adjustment range short-term delayed short-circuit release160 - 1600A
Rated voltage690 - 690V
Motor drive optionalYes
Type of control elementToggle
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA054034R1 | T4S 250 PR221DS-LS IN=160 4P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With under voltage release

Overload release current setting

64.0 .. 160A

Type of electrical connection of main circuit

Bolt connection

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

Number of poles

4

Motor drive integrated

Complete device with protection unit

Rated permanent current Iu

250A

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally open contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range undelayed short-circuit release

160 .. 1600A

With switched-off indicator

Integrated earth fault protection

Position of connection for main current circuit

Front side

Adjustment range short-term delayed short-circuit release

160 .. 1600A

Rated voltage

690 .. 690V

Motor drive optional

Type of control element

Toggle

Degree of protection (IP)

IP20