Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With under voltage releaseNo
Rated voltage690 - 690V
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release250 - 2500A
Rated permanent current Iu250A
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Type of electrical connection of main circuitBolt connection
Overload release current setting100.0 - 250A
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release250 - 2500A
DIN rail (top hat rail) mounting optionalNo
With switched-off indicatorNo
Position of connection for main current circuitFront side
Motor drive optionalYes
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Type of control elementToggle
Complete device with protection unitYes
Motor drive integratedNo
Number of poles3
Number of auxiliary contacts as normally open contact0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA054074R1 | T4L 250 PR221DS-I IN=250 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With under voltage release

Rated voltage

690 .. 690V

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

250 .. 2500A

Rated permanent current Iu

250A

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Type of electrical connection of main circuit

Bolt connection

Overload release current setting

100.0 .. 250A

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

250 .. 2500A

DIN rail (top hat rail) mounting optional

With switched-off indicator

Position of connection for main current circuit

Front side

Motor drive optional

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Type of control element

Toggle

Complete device with protection unit

Motor drive integrated

Number of poles

3

Number of auxiliary contacts as normally open contact

0

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.