Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With under voltage releaseNo
Rated permanent current Iu250A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz200kA
Adjustment range undelayed short-circuit release240.0 - 1920A
Overload release current setting64.0 - 160A
Integrated earth fault protectionNo
Number of auxiliary contacts as change-over contact0
Adjustment range short-term delayed short-circuit release96.0 - 1600A
Type of electrical connection of main circuitBolt connection
Number of poles3
With switched-off indicatorNo
Device constructionBuilt-in device fixed built-in technique
Type of control elementToggle
Number of auxiliary contacts as normally open contact0
Motor drive integratedNo
Position of connection for main current circuitFront side
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Degree of protection (IP)IP20
Motor drive optionalYes
Complete device with protection unitYes
Number of auxiliary contacts as normally closed contact0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA054100R1 | T4V 250 PR222DS/P-LSI IN=160 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With under voltage release

Rated permanent current Iu

250A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

200kA

Adjustment range undelayed short-circuit release

240.0 .. 1920A

Overload release current setting

64.0 .. 160A

Integrated earth fault protection

Number of auxiliary contacts as change-over contact

0

Adjustment range short-term delayed short-circuit release

96.0 .. 1600A

Type of electrical connection of main circuit

Bolt connection

Number of poles

3

With switched-off indicator

Device construction

Built-in device fixed built-in technique

Type of control element

Toggle

Number of auxiliary contacts as normally open contact

0

Motor drive integrated

Position of connection for main current circuit

Front side

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Degree of protection (IP)

IP20

Motor drive optional

Complete device with protection unit

Number of auxiliary contacts as normally closed contact

0

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.