Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated voltage690 - 690V
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
With switched-off indicatorNo
Number of poles4
Position of connection for main current circuitFront side
Rated permanent current Iu320A
Overload release current setting128.0 - 320A
Type of electrical connection of main circuitBolt connection
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Type of control elementToggle
Adjustment range short-term delayed short-circuit release192.0 - 3200A
Adjustment range undelayed short-circuit release480.0 - 3840A
Integrated earth fault protectionYes
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA054124R1 | T4N 320 PR222DS/P-LSIG IN=320 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated voltage

690 .. 690V

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

With switched-off indicator

Number of poles

4

Position of connection for main current circuit

Front side

Rated permanent current Iu

320A

Overload release current setting

128.0 .. 320A

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Type of control element

Toggle

Adjustment range short-term delayed short-circuit release

192.0 .. 3200A

Adjustment range undelayed short-circuit release

480.0 .. 3840A

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

With under voltage release

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Motor drive optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.