Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Number of poles4
Rated permanent current Iu250A
Degree of protection (IP)IP20
Type of control elementToggle
Motor drive integratedNo
Adjustment range short-term delayed short-circuit release- - -A
Overload release current setting- - -A
Integrated earth fault protectionNo
Motor drive optionalYes
Adjustment range undelayed short-circuit release- - -A
Number of auxiliary contacts as change-over contact0
With under voltage releaseNo
Type of electrical connection of main circuitBolt connection
Rated voltage690 - 690V
With switched-off indicatorNo
DIN rail (top hat rail) mounting optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA054281R1 | T4H 250 TMA 200-2000 4P F F INN=100%IN

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Number of poles

4

Rated permanent current Iu

250A

Degree of protection (IP)

IP20

Type of control element

Toggle

Motor drive integrated

Adjustment range short-term delayed short-circuit release

- .. -A

Overload release current setting

- .. -A

Integrated earth fault protection

Motor drive optional

Adjustment range undelayed short-circuit release

- .. -A

Number of auxiliary contacts as change-over contact

0

With under voltage release

Type of electrical connection of main circuit

Bolt connection

Rated voltage

690 .. 690V

With switched-off indicator

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.