Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Type of electrical connection of main circuitBolt connection
Number of poles4
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
With switched-off indicatorNo
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Type of control elementToggle
Position of connection for main current circuitFront side
Device constructionBuilt-in device fixed built-in technique
Rated permanent current Iu250A
With under voltage releaseNo
Integrated earth fault protectionNo
Motor drive integratedNo
Overload release current setting- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz200kA
Number of auxiliary contacts as change-over contact0
Suitable for DIN rail (top hat rail) mountingNo
Degree of protection (IP)IP20
Rated voltage690 - 690V
Motor drive optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA054288R1 | T4V 250 TMA 160-1600 4P F F INN=100%IN

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Type of electrical connection of main circuit

Bolt connection

Number of poles

4

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

With switched-off indicator

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Type of control element

Toggle

Position of connection for main current circuit

Front side

Device construction

Built-in device fixed built-in technique

Rated permanent current Iu

250A

With under voltage release

Integrated earth fault protection

Motor drive integrated

Overload release current setting

- .. -A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

200kA

Number of auxiliary contacts as change-over contact

0

Suitable for DIN rail (top hat rail) mounting

Degree of protection (IP)

IP20

Rated voltage

690 .. 690V

Motor drive optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.