Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
With under voltage releaseNo
Adjustment range short-term delayed short-circuit release- - -A
Rated permanent current Iu250A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Type of control elementToggle
Position of connection for main current circuitFront side
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP20
Motor drive optionalYes
Motor drive integratedNo
Type of electrical connection of main circuitBolt connection
With switched-off indicatorNo
Number of auxiliary contacts as normally closed contact0
Number of poles3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA054310R1 | T4L 250 MA 125-1750 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

With under voltage release

Adjustment range short-term delayed short-circuit release

- .. -A

Rated permanent current Iu

250A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Type of control element

Toggle

Position of connection for main current circuit

Front side

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP20

Motor drive optional

Motor drive integrated

Type of electrical connection of main circuit

Bolt connection

With switched-off indicator

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.