Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release320 - 3200A
Adjustment range undelayed short-circuit release320 - 3200A
With switched-off indicatorNo
Rated permanent current Iu400A
Overload release current setting128.0 - 320A
DIN rail (top hat rail) mounting optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
Number of poles3
Integrated earth fault protectionNo
Motor drive integratedNo
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitBolt connection
Complete device with protection unitYes
Motor drive optionalYes
Type of control elementToggle
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA054334R1 | T5S 400 PR221DS-I IN=320 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

320 .. 3200A

Adjustment range undelayed short-circuit release

320 .. 3200A

With switched-off indicator

Rated permanent current Iu

400A

Overload release current setting

128.0 .. 320A

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Suitable for DIN rail (top hat rail) mounting

With under voltage release

Number of poles

3

Integrated earth fault protection

Motor drive integrated

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Bolt connection

Complete device with protection unit

Motor drive optional

Type of control element

Toggle