Aleta.hr
Main Product Image

1SDA054337R1 | T5S 400 PR222DS/P-LSI IN=400 3P F F

Code: 1526420

ManufacturerABB
Catalog number1SDA054337R1
EAN code8015644554354

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Rated permanent current Iu400A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release600.0 - 4800A
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique
Overload release current setting160.0 - 400A
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally closed contact0
Adjustment range short-term delayed short-circuit release240.0 - 4000A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Complete device with protection unitYes
Number of poles3
Motor drive integratedNo
Degree of protection (IP)IP20
Type of control elementToggle
Motor drive optionalYes
Position of connection for main current circuitFront side
With switched-off indicatorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA054337R1 | T5S 400 PR222DS/P-LSI IN=400 3P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Rated permanent current Iu

400A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Integrated earth fault protection

Adjustment range undelayed short-circuit release

600.0 .. 4800A

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique

Overload release current setting

160.0 .. 400A

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Adjustment range short-term delayed short-circuit release

240.0 .. 4000A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Complete device with protection unit

Number of poles

3

Motor drive integrated

Degree of protection (IP)

IP20

Type of control element

Toggle

Motor drive optional

Position of connection for main current circuit

Front side

With switched-off indicator

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.