Technical specifications

Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu400A
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
Rated voltage690 - 690V
Motor drive integratedNo
Number of poles4
Position of connection for main current circuitFront side
Overload release current setting160.0 - 400A
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
Type of control elementToggle
Adjustment range short-term delayed short-circuit release400 - 4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range undelayed short-circuit release400 - 4000A
Motor drive optionalYes
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA054343R1 | T5S 400 PR221DS-I IN=400 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

400A

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

Rated voltage

690 .. 690V

Motor drive integrated

Number of poles

4

Position of connection for main current circuit

Front side

Overload release current setting

160.0 .. 400A

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Type of control element

Toggle

Adjustment range short-term delayed short-circuit release

400 .. 4000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range undelayed short-circuit release

400 .. 4000A

Motor drive optional

With under voltage release

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Integrated earth fault protection