  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu630A
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Number of poles3
Number of auxiliary contacts as normally open contact0
Rated voltage690 - 690V
Overload release current setting252.0 - 630A
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
With switched-off indicatorNo
Type of control elementToggle
Integrated earth fault protectionNo
With under voltage releaseNo
Adjustment range undelayed short-circuit release630 - 5985A
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release630 - 5985A
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA054412R1 | T5H 630 PR221DS-LS IN=630 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

630A

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Number of poles

3

Number of auxiliary contacts as normally open contact

0

Rated voltage

690 .. 690V

Overload release current setting

252.0 .. 630A

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

With switched-off indicator

Type of control element

Toggle

Integrated earth fault protection

With under voltage release

Adjustment range undelayed short-circuit release

630 .. 5985A

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

630 .. 5985A

Motor drive optional

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.