Aleta.hr
Main Product Image

1SDA054415R1 | T5H 630 PR222DS/P-LSIG IN=630 3P F F

Code: 1526498

ManufacturerABB
Catalog number1SDA054415R1
EAN code8015644555139

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Rated permanent current Iu630A
Adjustment range short-term delayed short-circuit release378.0 - 6300A
Integrated earth fault protectionYes
Adjustment range undelayed short-circuit release945.0 - 5985A
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
Position of connection for main current circuitFront side
Motor drive optionalYes
Number of auxiliary contacts as change-over contact0
Type of control elementToggle
Number of auxiliary contacts as normally open contact0
Motor drive integratedNo
Complete device with protection unitYes
Degree of protection (IP)IP20
Type of electrical connection of main circuitBolt connection
Overload release current setting252.0 - 630A
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Rated voltage690 - 690V
Number of poles3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA054415R1 | T5H 630 PR222DS/P-LSIG IN=630 3P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Rated permanent current Iu

630A

Adjustment range short-term delayed short-circuit release

378.0 .. 6300A

Integrated earth fault protection

Adjustment range undelayed short-circuit release

945.0 .. 5985A

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side

Motor drive optional

Number of auxiliary contacts as change-over contact

0

Type of control element

Toggle

Number of auxiliary contacts as normally open contact

0

Motor drive integrated

Complete device with protection unit

Degree of protection (IP)

IP20

Type of electrical connection of main circuit

Bolt connection

Overload release current setting

252.0 .. 630A

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Rated voltage

690 .. 690V

Number of poles

3

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.