Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Rated voltage690 - 690V
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu630A
Overload release current setting252.0 - 630A
With integrated under voltage releaseNo
Number of auxiliary contacts as normally open contact0
Number of poles4
Degree of protection (IP)IP20
Adjustment range short-term delayed short-circuit release630 - 5985A
Position of connection for main current circuitFront side
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release630 - 5985A
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Type of control elementToggle
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalNo
Motor drive integratedNo
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA054424R1 | T5L 630 PR221DS-LS IN=630 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Rated voltage

690 .. 690V

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

630A

Overload release current setting

252.0 .. 630A

With integrated under voltage release

Number of auxiliary contacts as normally open contact

0

Number of poles

4

Degree of protection (IP)

IP20

Adjustment range short-term delayed short-circuit release

630 .. 5985A

Position of connection for main current circuit

Front side

Integrated earth fault protection

Adjustment range undelayed short-circuit release

630 .. 5985A

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Type of control element

Toggle

Motor drive optional

DIN rail (top hat rail) mounting optional

Motor drive integrated

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.