Technical specifications

Motor drive integratedNo
Number of poles3
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP20
Rated permanent current Iu400A
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
Overload release current setting224.0 - 320A
With integrated under voltage releaseNo
Rated voltage690 - 690V
Number of auxiliary contacts as normally open contact0
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Type of control elementToggle
Adjustment range short-term delayed short-circuit release- - -A
Type of electrical connection of main circuitBolt connection
Motor drive optionalYes
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release1600 - 3200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz200kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA054452R1 | T5V 400 TMA 320-3200 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Motor drive integrated

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP20

Rated permanent current Iu

400A

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

Overload release current setting

224.0 .. 320A

With integrated under voltage release

Rated voltage

690 .. 690V

Number of auxiliary contacts as normally open contact

0

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Type of control element

Toggle

Adjustment range short-term delayed short-circuit release

- .. -A

Type of electrical connection of main circuit

Bolt connection

Motor drive optional

Complete device with protection unit

DIN rail (top hat rail) mounting optional

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

1600 .. 3200A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

200kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.