Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Number of poles4
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Overload release current setting350.0 - 500A
Rated permanent current Iu630A
Degree of protection (IP)IP20
Rated voltage690 - 690V
Position of connection for main current circuitFront side
Motor drive integratedNo
Number of auxiliary contacts as normally open contact0
Adjustment range undelayed short-circuit release2500 - 5000A
Type of control elementToggle
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Motor drive optionalYes
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz200kA
Type of electrical connection of main circuitBolt connection
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Adjustment range short-term delayed short-circuit release- - -A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA054475R1 | T5V 630 TMA 500-5000 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Number of poles

4

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Overload release current setting

350.0 .. 500A

Rated permanent current Iu

630A

Degree of protection (IP)

IP20

Rated voltage

690 .. 690V

Position of connection for main current circuit

Front side

Motor drive integrated

Number of auxiliary contacts as normally open contact

0

Adjustment range undelayed short-circuit release

2500 .. 5000A

Type of control element

Toggle

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Motor drive optional

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

200kA

Type of electrical connection of main circuit

Bolt connection

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Adjustment range short-term delayed short-circuit release

- .. -A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.