Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Rated permanent current Iu400A
Number of poles4
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP20
Overload release current setting224.0 - 320A
Rated voltage690 - 690V
Position of connection for main current circuitFront side
Motor drive integratedNo
Type of control elementToggle
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Complete device with protection unitYes
Type of electrical connection of main circuitBolt connection
Adjustment range short-term delayed short-circuit release- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
Motor drive optionalYes
Adjustment range undelayed short-circuit release1600 - 3200A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA054481R1 | T5H 400 TMA 320-3200 4P F F INN=100%IN

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Rated permanent current Iu

400A

Number of poles

4

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP20

Overload release current setting

224.0 .. 320A

Rated voltage

690 .. 690V

Position of connection for main current circuit

Front side

Motor drive integrated

Type of control element

Toggle

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Complete device with protection unit

Type of electrical connection of main circuit

Bolt connection

Adjustment range short-term delayed short-circuit release

- .. -A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Motor drive optional

Adjustment range undelayed short-circuit release

1600 .. 3200A