Rated short-circuit breaking capacity lcu at 400 V, 50 Hz200kA
Overload release current setting350.0 - 500A
Type of control elementToggle
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
Motor drive integratedNo
Type of electrical connection of main circuitBolt connection
Degree of protection (IP)IP20
Number of poles4
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Rated permanent current Iu630A
Rated voltage690 - 690V
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
Adjustment range undelayed short-circuit release2500 - 5000A
With under voltage releaseNo
Motor drive optionalYes
Adjustment range short-term delayed short-circuit release- - -A
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA054495R1 | T5V 630 TMA 500-5000 4P F F INN=100%IN

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

200kA

Overload release current setting

350.0 .. 500A

Type of control element

Toggle

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

Motor drive integrated

Type of electrical connection of main circuit

Bolt connection

Degree of protection (IP)

IP20

Number of poles

4

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Rated permanent current Iu

630A

Rated voltage

690 .. 690V

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

2500 .. 5000A

With under voltage release

Motor drive optional

Adjustment range short-term delayed short-circuit release

- .. -A

Integrated earth fault protection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.