Technical specifications

Overload release current setting- - -A
Number of poles3
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu250A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Type of control elementToggle
Motor drive integratedNo
Degree of protection (IP)IP20
Type of electrical connection of main circuitBolt connection
Position of connection for main current circuitFront side
With switched-off indicatorNo
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionNo
Complete device with protection unitYes
With under voltage releaseNo
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release- - -A
Motor drive optionalYes
Adjustment range short-term delayed short-circuit release- - -A
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA055074R1 | T4L 250 MA 10-140 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting

- .. -A

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

250A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Type of control element

Toggle

Motor drive integrated

Degree of protection (IP)

IP20

Type of electrical connection of main circuit

Bolt connection

Position of connection for main current circuit

Front side

With switched-off indicator

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Complete device with protection unit

With under voltage release

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

- .. -A

Motor drive optional

Adjustment range short-term delayed short-circuit release

- .. -A

Device construction

Built-in device fixed built-in technique